Advin Urology Surgical ESWL Lithotripter
Advin Urology Surgical ESWL Lithotripter
Advin Urology Surgical ESWL Lithotripter
Advin Urology Surgical ESWL Lithotripter
Advin Urology Surgical ESWL Lithotripter
Advin Urology Surgical ESWL Lithotripter

Advin Urology Surgical ESWL Lithotripter

Price 45000 USD ($)/ Piece

MOQ : 1 Piece

Advin Urology Surgical ESWL Lithotripter Specification

  • Function
  • Fragmentation of urinary calculi
  • Measurement Range
  • Stone size up to 30 mm
  • Features
  • Non-invasive, precise targeting, ergonomic design, digital interface, low maintenance
  • Instruments Type
  • Urology Surgical Equipment
  • Frequency
  • 60-120 shocks per minute
  • Display Type
  • Digital display with touch screen
  • Usage Type
  • Hospital, Clinic
  • Accuracy
  • High precision targeting (<2 mm error)
  • Shelf Life
  • 5 Years (with proper maintenance)
  • Storage Instructions
  • Store in clean, dry, temperature controlled environment
  • Equipment Type
  • ESWL Lithotripter
  • Material
  • Stainless Steel, ABS housing
  • Condition
  • New
  • Technology
  • Electrohydraulic shock wave generation
  • Portable
  • No
  • Wall Mounted
  • No
  • Magnification Power
  • Up to 15X (integrated fluoroscopy)
  • Real-Time Operation
  • Yes
  • Noise Level
  • Low Noise
  • Operating Type
  • Semi-Automatic
  • Use
  • Extracorporeal Shock Wave Lithotripsy for kidney stone treatment
  • Power Source
  • Electric
  • Power Consumption
  • 2500 W
  • Voltage
  • 220-240 V AC, 50/60 Hz
  • Dimension (L*W*H)
  • 1850 x 800 x 1200 mm
  • Weight
  • Approx. 250 kg
  • Color
  • White & Blue
  • Safety Mechanisms
  • Overload protection, emergency stop
  • Shock Rate
  • Selectable, user-defined
  • Patient Table
  • Motorized Height and Position Adjustment
  • Control System
  • Microprocessor based, programmable treatment
  • Imaging System
  • Integrated fluoroscopic and/or ultrasonic localization
  • Application
  • Kidney, ureter, bladder stones
  • Shock Wave Head Movement
  • Motorized, 3-axis adjustment
  • Pulse Energy
  • Up to 80 mJ per shock
 
 

About Advin Urology Surgical ESWL Lithotripter

The Advin ESWL is a highly effective, budget-friendly, and aesthetically designed system built for optimal performance in Extracorporeal Shock Wave Lithotripsy (ESWL). Engineered with carefully selected features, it delivers consistent results, making it a trusted solution for urology clinics worldwide.

Designed to treat all suitable urinary tract stones, the system achieves a typical stone-free rate of over 95%, ensuring high clinical success.

The Advin ESWL can be operated with either a C-arm X-ray imaging system or a spherical ultrasound attachment for precise stone localization. With a short break-even period, it offers not just clinical efficiency but also a profitable investment for your practice.

Advanced Features:

  • Non-invasive procedure eliminates risk of infection, bleeding, and pain

  • No general anesthesia required

  • Short treatment time fast recovery and high patient throughput

  • Safe and effective with high success rates

  • Focusing shock waves efficiently break stones into small fragments

  • No special infrastructure needed easy installation in existing setups

  • Wide movement range for flexible positioning and comfort

  • User-friendly design compatible with both patient and operator needs

  • C-arm X-ray imaging compatibility for precise stone targeting

  • Ultrasound attachment option for non-radiative stone localization



Innovative Shock Wave Technology

Equipped with electrohydraulic shock wave generation, the Advin ESWL Lithotripter enables efficient fragmentation of stones without invasive procedures. Its programmable microprocessor control ensures precision treatments that can be tailored for each patient. This dramatically improves clinical outcomes and patient comfort.


Advanced Imaging Integration

The lithotripter features an integrated fluoroscopic and ultrasonic imaging system capable of up to 15X magnification. This allows real-time, high-precision localization of urinary stones, decreases procedural errors, and streamlines workflow. Its digital display provides intuitive operation, ensuring ease for urology teams.


Ease of Use and Safety Features

The device offers motorized adjustments for both the shock wave head and patient table, ensuring exact positioning for each procedure. Enhanced safety is provided by overload protection and an emergency stop option, while the semi-automatic, low-noise operation sustains a calm clinical environment.

FAQ's of Advin Urology Surgical ESWL Lithotripter:


Q: How does the Advin Urology Surgical ESWL Lithotripter treat urinary stones?

A: This ESWL lithotripter uses electrohydraulic shock waves to fragment kidney, ureter, or bladder stones. The shock waves, targeted with integrated imaging, break stones into smaller pieces, allowing them to pass naturally through the urinary tract.

Q: What are the main benefits of using this lithotripter in a clinical setting?

A: Major benefits include non-invasive stone treatment, high-precision targeting using fluoroscopic or ultrasonic imaging, minimized patient discomfort, programmable treatments, low noise, and simple digital controls, making it suitable for efficient stone management in hospitals and clinics.

Q: When is this equipment typically used?

A: It is used during the treatment of patients with urinary tract stones in the kidney, ureter, or bladder who require non-invasive intervention for stone fragmentation without surgical procedures.

Q: Where should the lithotripter be installed and stored?

A: The Advin ESWL Lithotripter is designed for hospitals and clinics. It should be installed in a clean, dry, temperature-controlled environment as it is not wall-mounted or portable.

Q: What is the process for operating the lithotripter?

A: Operation involves positioning the patient on the motorized table, localizing the stone using the integrated imaging system, adjusting the shock wave head, and customizing treatment parameters via the digital interface. Safety mechanisms like emergency stop are available throughout the procedure.

Q: How precise is the targeting and what size stones can it treat?

A: With integrated high-magnification imaging and precision adjustment, the lithotripter can target stones with less than 2 mm error and is suitable for treating stones up to 30 mm in size.

Q: What maintenance and storage guidelines should be followed?

A: For optimal performance and a shelf life of up to five years, regular maintenance should be performed and the device should be stored in a clean, dry, temperature-stable location as specified in the storage instructions.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Urology Equipments Category

C Arm X Ray Machine, Advin

C Arm X Ray Machine, Advin

Price 15500 USD ($) / Piece

Minimum Order Quantity : 1 Piece

Wall Mounted : No

Operating Type : Other, Electric

Technology : Digital Imaging Technology

Use : Medical Imaging, Orthopedic, Surgical Procedures

Medical LED Light Source

Medical LED Light Source

Price 799 USD ($) / Piece

Minimum Order Quantity : 1 Piece

Wall Mounted : No

Operating Type : Other, Electrical / Manual Switch

Technology : LED Illumination

Use : For Endoscopy, Laparoscopy, Medical Examination

Endoscopic Irrigation Pump

Endoscopic Irrigation Pump

Price 1200 USD ($) / Piece

Minimum Order Quantity : 1 Piece

Wall Mounted : No

Operating Type : Other, Electric Powered

Technology : Microprocessor Controlled

Use : Endoscopic Surgery Irrigation

Urology HoLEP Instruments Set, Advin

Urology HoLEP Instruments Set, Advin

Price 17000 USD ($) / Piece

Minimum Order Quantity : 1 Piece

Wall Mounted : No

Operating Type : Manual

Technology : Holmium Laser Enucleation of the Prostate (HoLEP)

Use : Urology Surgical Procedures



Back to top