Artery Widening Balloon Devices
Artery Widening Balloon Devices
Artery Widening Balloon Devices
Artery Widening Balloon Devices
Artery Widening Balloon Devices
Artery Widening Balloon Devices
Artery Widening Balloon Devices
Artery Widening Balloon Devices

Artery Widening Balloon Devices

Price 55 USD ($)/ Piece

MOQ : 1 Piece

Artery Widening Balloon Devices Specification

  • Shelf Life
  • 3-5 Years (Sterile packaging)
  • Usage Type
  • Single Use, Disposable
  • Function
  • Mechanical Expansion of Narrowed Arteries
  • Storage Instructions
  • Store in Cool, Dry Place; Avoid direct sunlight
  • Instruments Type
  • Interventional Cardiology Device
  • Accuracy
  • High Precision Placement
  • Features
  • Radio-opaque Marker, Flexible Shaft, Trackable, Sterile
  • Measurement Range
  • Balloon diameters typically 1.5mm to 4.0mm
  • Equipment Type
  • PTCA Balloon Catheter
  • Material
  • Medical Grade Polymer/Plastic
  • Condition
  • New
  • Technology
  • Minimally Invasive Angioplasty Device
  • Portable
  • Yes
  • Wall Mounted
  • No
  • Real-Time Operation
  • Yes
  • Noise Level
  • Silent
  • Operating Type
  • Manual/Interventional
  • Use
  • Artery Widening, Angioplasty Procedure
  • Dimension (L*W*H)
  • Varying Lengths, Typically 140cm
  • Weight
  • Lightweight, Approx. 3-10 grams
  • Color
  • Blue with Transparent Balloon
  • Balloon Material
  • Non-compliant/ Semi-compliant polymer
  • Balloon Length
  • 10mm, 15mm, 20mm options
  • Marker Bands
  • Dual radio-opaque marker bands for positioning
  • Application
  • Percutaneous Transluminal Coronary Angioplasty (PTCA)
  • Inflation Pressure Range
  • Up to 16 atm (nominal)
  • Sterility
  • Ethylene Oxide (EO) Sterilized
  • Compliance
  • CE Marked, ISO 13485 Certified
  • Guidewire Compatibility
  • 0.014 inches
  • Packaging
  • Individual Blister Sterile Pack
  • Catheter Tip
  • Soft tip for atraumatic insertion
  • Latex Content
  • Latex-Free
 
 

About Artery Widening Balloon Devices

Advin Health Care is a trusted manufacturer of Artery Widening Balloon Devices designed to meet international quality standards. These devices are used in interventional cardiology and vascular procedures to dilate narrowed arteries, restore proper blood flow, and support effective treatment during angioplasty interventions.

Key Features

High-performance balloon for controlled and uniform artery dilation
Excellent trackability for smooth navigation through vascular pathways
Flexible design for accessing complex and tortuous anatomy
Uniform pressure distribution for safe and effective expansion
Radiopaque markers for precise positioning under imaging guidance
Compatible with standard guide wires and angioplasty systems

Certifications

We are certified with CE, ISO 13485, and ISO 9001 standards.

Product Keywords

Artery Widening Balloon Device, Angioplasty Balloon Catheter, PTCA Balloon Device, Vascular Balloon Dilatation System, Interventional Balloon Catheter, Coronary Artery Dilatation Device



, , , , ,

Dispositivo de baln para ensanchamiento arterial, catter de baln para angioplastia, dispositivo de baln para PTCA, sistema de dilatacin vascular con baln, catter de baln intervencionista, dispositivo de dilatacin de arteria coronaria

Dispositif   ballonnet d'largissement artriel, cathter   ballonnet d'angioplastie, dispositif   ballonnet pour angioplastie coronaire transluminale percutane (ACTP), systme de dilatation vasculaire par ballonnet, cathter   ballonnet interventionnel, dispositif de dilatation des artres coronaires



Advanced Balloon Technology for Heart Health

Engineered for use in angioplasty, our PTCA balloon catheter offers precise, controlled artery dilation. The non-compliant or semi-compliant balloon material ensures reliable performance, while the soft tip design facilitates gentle navigation through the vascular system, minimizing trauma and enhancing procedural safety.


Safety and Precision You Can Trust

Each device incorporates dual radio-opaque marker bands to deliver high positional accuracy under imaging, supporting clinicians during intricate coronary procedures. Ethylene oxide sterilization and latex-free materials further ensure patient safety, while adherence to CE mark and ISO 13485 exemplifies commitment to international quality and compliance standards.


Ease of Use and Versatility

Available in three balloon lengths and numerous diameters, the lightweight, trackable shaft is compatible with 0.014-inch guidewires, providing flexibility across varied coronary anatomies. Designed for single use, the catheter comes in sterile blister packaging, offering convenience and reducing risk of cross-contamination for healthcare providers.

FAQ's of Artery Widening Balloon Devices:


Q: How is the Artery Widening Balloon Device used during an angioplasty procedure?

A: The device is introduced into the narrowed artery via a minimally invasive percutaneous approach, typically over a 0.014-inch guidewire. Once positioned using the dual radio-opaque markers for guidance, the balloon is inflated to mechanically expand the artery, restoring optimal blood flow.

Q: What are the main material and safety features of this PTCA balloon catheter?

A: Made from a medical-grade non-compliant or semi-compliant polymer, the catheter is latex-free and features a soft tip to prevent vessel trauma. It is ethylene oxide sterilized, presented in an individual sterile blister pack, and is CE marked and ISO 13485 certified for quality assurance.

Q: When should I choose between the different balloon lengths available?

A: Balloon length selection (10mm, 15mm, or 20mm) depends on the lesion's length and anatomical location. Shorter balloons are ideal for focal stenosis, while longer options are preferred for extended or diffuse artery narrowing.

Q: Where can these balloon catheters be used, and who are the ideal users?

A: These devices are designed for use in catheterization laboratories by interventional cardiologists. They are suitable for hospital settings during percutaneous transluminal coronary angioplasty (PTCA) procedures.

Q: What are the benefits of using dual radio-opaque marker bands?

A: Dual marker bands enhance visibility under fluoroscopy, allowing clinicians to position the balloon catheter with high precision, thereby improving procedural success and minimizing the risk of improper deployment.

Q: How should the device be stored before use?

A: Store the balloon catheter in its original sterile blister pack, in a cool, dry place away from direct sunlight, to maintain sterility and integrity throughout its 3-5 year shelf life.

Q: What makes this balloon catheter easy to use during procedures?

A: The lightweight, flexible shaft and compatibility with 0.014-inch guidewires ensure excellent deliverability and ease of trackability through complex arterial pathways, supporting efficient and safe angioplasty.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Cardiology Products Category

Clinical Vascular Snare Basket

Clinical Vascular Snare Basket

Price 70 USD ($) / Piece

Minimum Order Quantity : 1 Piece

Condition : New

Use : Endovascular Foreign Body Retrieval

Shelf Life : 3 Years

Equipment Type : Clinical Vascular Snare Basket

Disposable 2-Way Manifold

Disposable 2-Way Manifold

Price 2 USD ($) / Piece

Minimum Order Quantity : 1 Piece

Condition : New

Use : Infusion Therapy, Medical Fluid Administration

Shelf Life : 3 Years

Equipment Type : Disposable 2Way Manifold

Mullin  Sheath

Mullin Sheath

Price 45 USD ($) / Piece

Minimum Order Quantity : 1 Piece

Condition : New

Use : Urological/Medical Surgical Procedures

Shelf Life : 5 years

Equipment Type : Surgical Sheath

Clinical Grade Access Sheath

Clinical Grade Access Sheath

Price 6 USD ($) / Piece

Minimum Order Quantity : 1 Piece

Condition : New

Use : Urological procedures, access for endoscopic instruments

Shelf Life : 5 years

Equipment Type : Clinical Grade Access Sheath



Back to top