Cardiovascular Inflation Device
Cardiovascular Inflation Device
Cardiovascular Inflation Device
Cardiovascular Inflation Device
Cardiovascular Inflation Device
Cardiovascular Inflation Device
Cardiovascular Inflation Device
Cardiovascular Inflation Device
Cardiovascular Inflation Device
Cardiovascular Inflation Device
Cardiovascular Inflation Device
Cardiovascular Inflation Device

Cardiovascular Inflation Device

Price 15 USD ($)/ Piece

MOQ : 1 Piece

Cardiovascular Inflation Device Specification

  • Instruments Type
  • Interventional Cardiology Device
  • Measurement Range
  • 0-30 atm (0-441 psi)
  • Shelf Life
  • 5 years
  • Display Type
  • Analog Pressure Gauge
  • Usage Type
  • Single Use, Disposable
  • Function
  • Precise inflation and deflation control
  • Accuracy
  • ±2% full scale
  • Storage Instructions
  • Store in a cool, dry place away from direct sunlight
  • Features
  • Clear pressure gauge, Ergonomic handle, High visibility scale
  • Material
  • Polycarbonate, Medical Grade Polymer
  • Condition
  • New
  • Technology
  • Manual Mechanical Inflation
  • Portable
  • Yes
  • Wall Mounted
  • No
  • Real-Time Operation
  • Yes
  • Noise Level
  • Silent Operation
  • Operating Type
  • Manual
  • Use
  • Balloon angioplasty, Stent deployment
  • Power Source
  • Not required (Manual)
  • Dimension (L*W*H)
  • Approx. 20 cm x 6 cm x 4 cm
  • Weight
  • Approx. 300 g
  • Color
  • Blue, Transparent
  • Release Mechanism
  • Quick Release Valve
  • Connector Type
  • Luer Lock
  • Minimum Graduation
  • 1 atm
  • Piston Volume Capacity
  • 20 ml
  • Latex-Free
  • Yes
  • CE Marked
  • Yes
  • Equipment Type
  • Cardiovascular Inflation Device
  • Barcode
  • Available
  • Maximum Pressure
  • 30 atm
  • Sterility
  • EO Sterilized
  • Temperature Range
  • 15°C to 30°C
 
 

About Cardiovascular Inflation Device

The Advin Cardiovascular Inflation Device is used to control and monitor balloon inflation during angioplasty and other cardiac procedures.
It allows physicians to apply precise pressure for safe and effective balloon expansion inside the arteries.
This device is designed with accuracy and ease of use, ensuring patient safety and reliable outcomes.

Advanced Features

  • Accurate pressure control for balloon inflation

  • Clear pressure gauge for easy monitoring

  • Ergonomic design for comfortable handling

  • Reliable performance during angioplasty procedures

  • Durable and safe construction

Product Keywords

Cardiovascular Inflation Device, Balloon Inflation Device, PTCA Inflator, Angioplasty Inflation Device, Interventional Cardiology Inflation Tool, Balloon Pressure Device

جهاز نفخ القلب والأوعية الدموية، جهاز نفخ البالون، جهاز نفخ رأب الأوعية التاجية عن طريق الجلد، جهاز نفخ رأب الأوعية، أداة نفخ طب القلب التدخلي، جهاز ضغط البالون

Устройство для надувания сердечно-сосудистых баллонов, устройство для надувания баллонов, устройство для надувания баллонов при ЧКВ, устройство для надувания баллонов при ангиопластике, инструмент для надувания баллонов в интервенционной кардиологии, устройство для измерения давления в баллоне.

Dispositivo de inflado cardiovascular, dispositivo de inflado de balón, inflador para PTCA, dispositivo de inflado para angioplastia, herramienta de inflado para cardiología intervencionista, dispositivo de presión de balón

Dispositif de gonflage cardiovasculaire, dispositif de gonflage de ballonnet, inflateur pour angioplastie coronaire transluminale percutanée (ACTP), dispositif de gonflage pour angioplastie, outil de gonflage en cardiologie interventionnelle, dispositif de pression du ballonnet


Precision and Safety for Cardiovascular Procedures

Engineered for reliability, the Cardiovascular Inflation Device offers manual, real-time inflation with a clear analog gauge and a high-visibility scale. Its latex-free, EO-sterilized construction and CE certification ensure uncompromised safety during angioplasty and stent deployment. The quick release valve enables efficient pressure adjustment and deflation, supporting smooth procedural workflow.


User-Friendly Design for Enhanced Control

The device incorporates an ergonomic handle for comfortable grip during prolonged procedures. The transparent body and high-contrast scale provide clear, accurate pressure readings. Its Luer Lock connector secures easy attachment to intervention balloons, while the lightweight, disposable design adds to user convenience and cross-contamination prevention.


Versatility and Convenience for Modern Practices

Suitable for operating temperatures between 15C and 30C, this device is built for versatility in diverse clinical settings. As it requires no external power source, it remains portable and reliable-even during power outages. With a five-year shelf life, the product supports inventory stability for hospitals and clinics across India and international markets.

FAQ's of Cardiovascular Inflation Device:


Q: How is the Cardiovascular Inflation Device used during procedures?

A: The device is manually operated to inflate or deflate angioplasty balloons or stents. The ergonomic handle allows precise pressure control, visible on the clear analog gauge. The Luer Lock connector ensures secure attachment, and inflation is monitored in real-time with graduation marks for accuracy.

Q: What safety features are included in this inflation device?

A: Safety is prioritized through EO sterilization, latex-free materials, and CE marking. The quick release valve allows for immediate pressure reduction when necessary, minimizing procedural risk to patients.

Q: When should this device be used in cardiology interventions?

A: This inflation device is intended for use during balloon angioplasty and stent deployment in interventional cardiology, where controlled and precise inflation or deflation of cardiac devices is required.

Q: Where can the Cardiovascular Inflation Device be stored and used?

A: Store the device in a cool, dry area away from direct sunlight, between 15C and 30C. It is portable and suitable for use in hospitals, clinics, and field settings where interventional cardiovascular procedures are performed.

Q: What is the process for connecting and operating the device?

A: Attach the device to the balloon or stent using the Luer Lock connector. Use the ergonomic handle to manually adjust pressure. Real-time pressure is shown on the analog gauge, and the quick release valve enables rapid deflation when needed.

Q: What are the benefits of using this manual inflation device?

A: Benefits include high pressure capability (up to 30 atm), sterile and safe materials, silent operation, precise control with 2% full-scale accuracy, and no requirement for electricity, making it reliable and easy to use in any clinical scenario.

Q: Is the Cardiovascular Inflation Device reusable or disposable?

A: The device is single-use and disposable, reducing infection risk and ensuring fresh, sterile equipment for every procedure.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Cardiology Products Category

Cath Lab Cardiovascular Devices

Cath Lab Cardiovascular Devices

Price 110 USD ($) / Piece

Minimum Order Quantity : 1 Piece

Shelf Life : 25 Years

Measurement Range : As per device type (catheters, wires, stents, etc.)

Instruments Type : Guidewire, Catheter, Balloon, Stent, Infusion Device

Noise Level : Low

Advin Coronary Devices

Advin Coronary Devices

Price 10 USD ($) / Piece

Minimum Order Quantity : 1 Piece

Shelf Life : 5 Years

Measurement Range : Varies by device type

Instruments Type : Interventional Device

Noise Level : Silent Operation

Cardiology Manifold 2 Way

Cardiology Manifold 2 Way

Price 2 USD ($) / Piece

Minimum Order Quantity : 1 Piece

Shelf Life : 5 Years

Measurement Range : Up to 500 psi

Instruments Type : Catheterization Laboratory Accessory

Noise Level : Silent Operation

Cath Lab Interventional Cardiology Tools

Cath Lab Interventional Cardiology Tools

Price 85 USD ($) / Piece

Minimum Order Quantity : 1 Piece

Shelf Life : 25 Years (Depending on device)

Measurement Range : Varies as per catheter/wire specifications

Instruments Type : Angioplasty Balloons, Catheters, Guide Wires, Stents, Syringes, Compression Bands

Noise Level : Silent Operation



Back to top