Endovascular Embolectomy Catheter
Endovascular Embolectomy Catheter
Endovascular Embolectomy Catheter
Endovascular Embolectomy Catheter
Endovascular Embolectomy Catheter
Endovascular Embolectomy Catheter
Endovascular Embolectomy Catheter
Endovascular Embolectomy Catheter
Endovascular Embolectomy Catheter
Endovascular Embolectomy Catheter
Endovascular Embolectomy Catheter
Endovascular Embolectomy Catheter

Endovascular Embolectomy Catheter

Price 30 USD ($)/ Piece

MOQ : 1 Piece

Endovascular Embolectomy Catheter Specification

  • Usage Type
  • Single Use (Disposable)
  • Shelf Life
  • 2-5 Years (as per manufacturer)
  • Instruments Type
  • Catheter
  • Accuracy
  • High (precise distal embolus engagement and retrieval)
  • Measurement Range
  • Compatible with vessel diameters 1.5mm-7mm
  • Features
  • Flexible shaft, radiopaque marker, hydrophilic coating, balloon tip design for clot retrieval
  • Storage Instructions
  • Store in a dry, cool place away from direct sunlight
  • Function
  • Embolectomy (clot removal) by endovascular approach
  • Equipment Type
  • Endovascular Embolectomy Catheter
  • Material
  • Medical Grade Polymer (such as Polyurethane or Nylon)
  • Condition
  • New
  • Technology
  • Minimally Invasive Endovascular Technology
  • Portable
  • Yes
  • Wall Mounted
  • No
  • Real-Time Operation
  • Yes
  • Noise Level
  • Silent Operation
  • Operating Type
  • Manual
  • Use
  • Removal of Embolus/Clots from Blood Vessels
  • Power Source
  • Not Required/Manual
  • Dimension (L*W*H)
  • Catheter Length commonly 60-120 cm, Diameter: 4-7 Fr
  • Weight
  • Lightweight (typically <25g per catheter)
  • Color
  • Transparent/Blue (as per manufacturer design)
  • Regulatory Approval
  • CE Marked / US FDA 510(k) cleared (as per availability)
  • Sterility
  • Sterile, EO (Ethylene Oxide) sterilized
  • Packaging
  • Individually packed in sterile pouch
  • Intended Patient Population
  • Adults and Pediatric patients (size selection dependent)
  • Radiopacity
  • Radiopaque marker present for fluoroscopic guidance
  • Compatibility
  • Compatible with standard guide wires and syringes
  • Connector Type
  • Luer Lock compatible
  • Catheter Tip
  • Soft and atraumatic for vessel protection
  • Latex Content
  • Latex-Free
  • Balloon Inflation Volume
  • 1.0-1.5 ml (according to catheter size)
 
 

About Endovascular Embolectomy Catheter

The endovascular embolectomy catheter is designed to support effective clot removal while minimizing trauma to the vessel wall. Its controlled design allows clinicians to navigate vessels accurately and engage emboli with confidence. Advin Health Care manufactures this catheter with a strong focus on clinical safety, reliability, and consistent performance. The catheter is suitable for various endovascular procedures, helping restore blood flow and support efficient vascular intervention workflows.

Advanced Features

  • Designed for minimally invasive endovascular clot removal

  • Supports controlled engagement and retrieval of emboli

  • Smooth catheter shaft for safe vascular navigation

  • Intended for single-use clinical applications


Product Keywords
Endovascular Embolectomy Catheter, Embolectomy Balloon Catheter, Endovascular Thrombectomy Catheter, Clot Removal Catheter, Vascular Embolectomy Device, Balloon Catheter for Embolus Removal

U3 3aU U UU1U U3 UUU 3aU U U3 3aU U UU1U U3 2U UU U2 3aU U UU1U U3 UUU U2U U

NNN N N12 342NoNNN12341 N1434NoN3414 , 341212N1 oNNN N N1434NoN3414 , oNNN N N12 342NoNNN12341 NN3414NoN3414 , oNNN N N 12 N NN3414342, NNNN341NN234 N N34NN NN341 N1434NoN3414 , 341212N1 oNNN N N 12 N N1434342.

CatAter de embolectomAa endovascular, catAter de balA3n para embolectomAa, catAter de trombectomAa endovascular, catAter para extracciA3n de coAgulos, dispositivo de embolectomAa vascular, catAter de balA3n para extracciA3n de Ambolos

CathAter d'embolectomie endovasculaire, cathAter A ballonnet d'embolectomie, cathAter de thrombectomie endovasculaire, cathAter d'extraction de caillot, dispositif d'embolectomie vasculaire, cathAter A ballonnet pour l'extraction d'emboles



Precise and Safe Clot Removal

This embolectomy catheter is engineered for minimally invasive removal of blood clots from vessels, ensuring high precision with its radiopaque marker and soft, atraumatic tip. Its balloon can be gently inflated to match vessel size, minimizing trauma and enhancing safety during clot retrieval in both adults and children.


Designed for Versatile Clinical Application

With compatibility for standard guide wires and syringes, along with a Luer Lock connector, this catheter integrates seamlessly into various clinical workflows. Its wide sizing range and flexible shaft address multiple vessel diameters, supporting diverse endovascular procedures while ensuring operator control and comfort.


Quality and Compliance Assured

Produced from medical-grade, latex-free polymers, each catheter is individually sterilized and packaged, with shelf lives of 2 to 5 years. The device meets stringent CE Mark and US FDA 510(k) clearance requirements (as available), underlining its reliability and international safety standards.

FAQ's of Endovascular Embolectomy Catheter:


Q: How is the Endovascular Embolectomy Catheter used during clot removal procedures?

A: The catheter is carefully inserted into the targeted blood vessel and navigated using fluoroscopic guidance thanks to its radiopaque marker. Once positioned at the embolus, the balloon is inflated with 1.0-1.5 ml (as per catheter size) to firmly engage the clot, which is then gently retracted and removed from the vessel.

Q: What makes this catheter safe for vessel walls and patients?

A: A soft, atraumatic tip minimizes the risk of vessel injury during insertion and retrieval. Additionally, the catheter is latex-free, has a hydrophilic coating for smooth navigation, and comes sterile-helping ensure patient safety for both adults and pediatric cases.

Q: When should this catheter be considered for use?

A: It is suitable for endovascular procedures requiring the removal of emboli or thrombi in patients where minimally invasive intervention is indicated. Appropriate catheter size should be selected based on patient age and vessel diameter.

Q: Where can this catheter be utilized?

A: This device is designed for use in hospitals, catheterization laboratories, and other settings that provide interventional vascular procedures under fluoroscopic or real-time imaging guidance.

Q: What are the main benefits of using this embolectomy catheter?

A: Benefits include precise clot engagement thanks to balloon inflation and radiopaque guidance, minimized vessel trauma due to its soft tip, and reduced contamination risk from single-use, EO-sterilized packaging. Its compatibility with common medical accessories further aids procedural efficiency.

Q: How should the catheter be stored prior to use?

A: It should be kept in a dry, cool location away from direct sunlight, in its original sterile pouch, to maintain sterility and extend its shelf life.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Cardiology Products Category

3-way infusion manifold Angioway

3-way infusion manifold Angioway

Price 2.00 USD ($) / Piece

Minimum Order Quantity : 1 Piece

Condition : New

Accuracy : Leakproof up to 4.5 bar

Wall Mounted : No

Noise Level : Silent operation

Pressure Injection Set

Pressure Injection Set

Price 25 USD ($) / Set

Minimum Order Quantity : 1 Set

Condition : New

Accuracy : High precision for controlled fluid delivery

Wall Mounted : No

Noise Level : Silent Operation

Flexible Stripped Guide Wire

Flexible Stripped Guide Wire

Price 25 USD ($) / Piece

Minimum Order Quantity : 1 Piece

Condition : New

Accuracy : High positional accuracy for vessel navigation

Wall Mounted : No

Noise Level : Silent operation

Cardiac Introducer Sheath

Cardiac Introducer Sheath

Price 70 USD ($) / Piece

Minimum Order Quantity : 1 Piece



Back to top