Endovascular Inflation Device
Endovascular Inflation Device
Endovascular Inflation Device
Endovascular Inflation Device
Endovascular Inflation Device
Endovascular Inflation Device
Endovascular Inflation Device
Endovascular Inflation Device
Endovascular Inflation Device
Endovascular Inflation Device
Endovascular Inflation Device
Endovascular Inflation Device

Endovascular Inflation Device

Price 15 USD ($)/ Piece

MOQ : 1 Piece

Endovascular Inflation Device Specification

  • Accuracy
  • 3% at full scale
  • Features
  • Pressure gauge, quick release, ergonomic grip, precise pressure control, compatible with standard inflation accessories
  • Function
  • Controlled inflation and deflation of angioplasty balloons
  • Storage Instructions
  • Store in a dry, cool place, avoid direct sunlight
  • Instruments Type
  • Interventional cardiology/endovascular device
  • Usage Type
  • Single use / disposable
  • Display Type
  • Analog pressure gauge
  • Measurement Range
  • 030 atm (atmospheres)
  • Shelf Life
  • 3 years (sealed pack)
  • Equipment Type
  • Endovascular Inflation Device
  • Material
  • Polycarbonate, metal (stainless steel/plastic composite)
  • Condition
  • New
  • Technology
  • Manual mechanical inflation technology
  • Portable
  • Yes
  • Wall Mounted
  • No
  • Real-Time Operation
  • Yes
  • Noise Level
  • Silent operation
  • Operating Type
  • Manual
  • Use
  • Balloon dilation, stent placement and angioplasty procedures
  • Power Source
  • Manual
  • Dimension (L*W*H)
  • Approx. 24 cm x 6 cm x 3.5 cm
  • Weight
  • Approx. 250 g
  • Color
  • Transparent with blue/green handle accents
  • Connector Type
  • Standard luer lock
  • Handle Ergonomics
  • Non-slip textured grip
  • Maximum Pressure
  • 30 atm / 441 psi
  • Minimum Pressure Increment
  • 0.2 atm
  • Gauge Type
  • Rotary analog dial
  • Pressure Release Mechanism
  • One-touch rapid deflation button
  • Packaging
  • Individually packed, blister pack
  • Operating Temperature
  • 15C-30C
  • Latex Free
  • Yes
  • Compliance Standard
  • ISO 10555-1, CE marked
  • Sterility
  • Sterile (EO sterilized)
  • Application Area
  • Cath lab, vascular surgery, interventional radiology
 
 

About Endovascular Inflation Device

Advin Endovascular Inflation Device is designed to provide precise control during balloon inflation in angioplasty and other endovascular procedures. It ensures accurate pressure management for safe and effective vessel dilation. The device is user-friendly, reliable, and compatible with standard balloon catheters used in hospitals.

Advanced Features:


  • Precise pressure control for safe balloon inflation
  • Ergonomic and user-friendly design for easy handling

  • Reliable and consistent performance in clinical procedures

  • Compatible with standard balloon catheters

  • Supports coronary, peripheral, and vascular interventions

Product Keywords


Endovascular Inflation Device, Balloon Inflation Device, PTCA Inflation System, Cardiology Inflation Unit, Controlled Pressure Inflator

جهاز نفخ الأوعية الدموية، جهاز نفخ البالون، نظام نفخ رأب الأوعية التاجية عن طريق الجلد، وحدة نفخ القلب، جهاز نفخ بضغط متحكم به

Эндоваскулярное устройство для раздувания баллона, устройство для раздувания баллона, система для раздувания баллона при ЧКВ, кардиологический блок для раздувания баллона, устройство для раздувания баллона под контролируемым давлением.

Dispositivo de inflado endovascular, dispositivo de inflado con balón, sistema de inflado para PTCA, unidad de inflado cardiológico, inflador de presión controlada

Dispositif de gonflage endovasculaire, dispositif de gonflage par ballonnet, système de gonflage pour angioplastie coronaire transluminale percutanée (ACTP), unité de gonflage en cardiologie, gonfleur à pression contrôlée


High-Precision Rotary Dial for Reliable Control

The rotary analog dial pressure gauge allows clinicians to incrementally adjust and monitor inflation with a fine 0.2 atm resolution, ensuring high precision during sensitive interventional procedures. With a measurement range of 030 atm and 3% accuracy at full scale, practitioners can achieve optimal results and safer outcomes.


Designed for Comfort and Safety in Demanding Settings

Ergonomically designed with a non-slip, textured grip, the device offers confident handling even during prolonged procedures. Manufactured from polycarbonate and robust stainless steel/plastic composites, each unit is individually EO sterilized and provided in a blister pack to ensure maximum sterility and patient safety.


Versatile Application and Simple Operation

Compatible with standard inflation accessories via a luer lock connector, this manually operated inflation device is suitable for balloon dilation, stent placements, and angioplasty. The pressure can be quickly released using its user-friendly one-touch button, delivering both outstanding control and rapid response in critical moments.

FAQs of Endovascular Inflation Device:


Q: How do I use the Endovascular Inflation Device during angioplasty?

A: To use, connect the standard luer lock to the angioplasty balloon catheter. Rotate the analog dial to incrementally increase pressure, monitoring the gauge for the desired value. The device allows precise adjustments with a minimum increment of 0.2 atm. When finished, use the one-touch rapid deflation button to release pressure quickly and safely.

Q: What are the main benefits of choosing this inflation device over others?

A: Key benefits include its precise rotary analog gauge with high accuracy (3% at full scale), ergonomic non-slip grip for better handling, and rapid pressure release mechanism. It is sterile, individually packed, latex-free, silent during use, and compatible with standard inflation accessories, making it highly reliable for single-use procedures.

Q: When and where is this device most commonly used?

A: This inflation device is typically used in cath labs, vascular surgery, and interventional radiology settings. It is essential during balloon dilation, stent placements, and angioplasty procedures, whenever controlled balloon inflation is required.

Q: What is the process for ensuring device sterility before use?

A: Each device is EO (ethylene oxide) sterilized and individually sealed in a blister pack. Before opening, confirm the packaging is intact and the product is within its 3-year shelf life. Open the blister pack in a sterile field to maintain sterility during the procedure.

Q: How do I store the Endovascular Inflation Device prior to use?

A: Store the device in a cool, dry place away from direct sunlight. Ensure the package remains sealed and untouched until use. Proper storage helps maintain sterility and product integrity throughout its 3-year shelf life.

Q: What makes the device suitable for single-use applications?

A: It is designed as a disposable device, sterilized and individually packaged to prevent cross-contamination. After use, it should be discarded following hospital protocols for safe disposal of single-use medical devices.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Cardiology Products Category

Angiography Syringe

Angiography Syringe

Price 2 USD ($) / Piece

Minimum Order Quantity : 1 Parcel

Portable : Yes

Equipment Type : Angiography Syringe

Usage Type : Singleuse, Disposable

Noise Level : Silent

Heart Perfusion Syringe

Heart Perfusion Syringe

Price 2 USD ($) / Piece

Minimum Order Quantity : 1 Piece

Portable : Yes

Equipment Type : Heart Perfusion Syringe

Usage Type : Reusable

Noise Level : Silent Operation

Nitinol Vascular Basket

Nitinol Vascular Basket

Price 60 USD ($) / Piece

Minimum Order Quantity : 1 Piece

Portable : Yes

Equipment Type : Vascular Basket

Usage Type : Medical

Noise Level : Silent

Vascular Access Devices

Vascular Access Devices

Price 6 USD ($) / Piece

Minimum Order Quantity : 1 Piece

Portable : Yes

Equipment Type : Vascular Access Device / Introducer Sheath

Usage Type : Single Use Only

Noise Level : Silent / None



Back to top