ERCP Biliary Flow Stent  10 mm x 100 mm
ERCP Biliary Flow Stent  10 mm x 100 mm
ERCP Biliary Flow Stent  10 mm x 100 mm
ERCP Biliary Flow Stent  10 mm x 100 mm
ERCP Biliary Flow Stent  10 mm x 100 mm
ERCP Biliary Flow Stent  10 mm x 100 mm
ERCP Biliary Flow Stent  10 mm x 100 mm
ERCP Biliary Flow Stent  10 mm x 100 mm
ERCP Biliary Flow Stent  10 mm x 100 mm
ERCP Biliary Flow Stent  10 mm x 100 mm
ERCP Biliary Flow Stent  10 mm x 100 mm
ERCP Biliary Flow Stent  10 mm x 100 mm

ERCP Biliary Flow Stent 10 mm x 100 mm

Price 5 USD ($)/ Piece

MOQ : 1 Piece

ERCP Biliary Flow Stent 10 mm x 100 mm Specification

  • Instruments Type
  • Medical Disposable, Gastroenterology Device
  • Function
  • Maintains biliary duct patency, Facilitates bile drainage
  • Usage Type
  • Single Use
  • Features
  • Side holes, Radiopaque line for enhanced visibility, Flexible and kink-resistant design, Smooth surface to reduce tissue irritation
  • Shelf Life
  • 2-3 Years
  • Storage Instructions
  • Store in a cool, dry place, away from direct sunlight
  • Equipment Type
  • ERCP Biliary Flow Stent
  • Material
  • Medical Grade Polymer
  • Condition
  • New
  • Technology
  • Endoscopic Placement
  • Portable
  • Yes
  • Wall Mounted
  • No
  • Real-Time Operation
  • Yes
  • Noise Level
  • Silent
  • Operating Type
  • Manual
  • Use
  • Biliary Drainage, Obstruction Treatment
  • Dimension (L*W*H)
  • 100 mm (Length) x 10 mm (Diameter)
  • Weight
  • Lightweight (Approx. <10g)
  • Color
  • Blue
  • Radiopacity
  • Radiopaque stripes for X-ray visibility
  • Packaging
  • Individually packed in sterile blister pack
  • Application
  • Hospital, Clinic, Endoscopy Center
  • Stent Length
  • 100 mm
  • Stent Diameter
  • 10 mm
  • Sterility
  • Sterile EO (Ethylene Oxide) Gas
  • Disposability
  • Disposable, Single Use Only
  • Connector
  • Flared Ends to prevent migration
  • Intended Patients
  • Adult & Pediatric patients with biliary disorders
  • Compatibility
  • Compatible with standard ERCP accessories
  • Tip Type
  • Rounded, Atraumatic
 
 

About ERCP Biliary Flow Stent 10 mm x 100 mm

The ERCP Biliary Flow Stent 10 mm 100 mm is used to manage biliary strictures by offering a stable and reliable passage for bile drainage. Its 10 mm diameter with a 100 mm length provides extended coverage, making it suitable for longer obstructed segments. The design ensures proper duct patency, helping reduce discomfort and prevent complications associated with biliary blockage. Built with durable, high-quality materials, it supports dependable performance during ERCP procedures, and Advin Health Care ensures strict quality standards to promote safe and efficient clinical outcomes.


Advanced Features:

  • 10 mm 100 mm size suitable for long biliary obstructions

  • Smooth lumen for continuous and steady bile flow

  • Secure placement for reliable duct support

  • Constructed from durable medical-grade materials



Advanced Design for Biliary Care

The ERCP Biliary Flow Stent is engineered with a flexible, kink-resistant structure and smooth surface to minimize tissue irritation during placement and use. Its flared ends are specifically designed to prevent migration, while side holes facilitate optimal bile drainage. Suitable for both adult and pediatric patients, it offers reliable performance in diverse clinical settings.


Reliable Visibility and Compatibility

This stent is equipped with radiopaque stripes and a radiopaque line, enhancing its visibility under X-ray imaging to ensure accurate placement. It is compatible with standard ERCP accessories, streamlining the procedure for gastroenterology teams and improving clinical outcomes.


Safe, Sterile, and Convenient

Packaged in a sterile, single-use blister pack and sterilized using Ethylene Oxide Gas, the stent prioritizes patient safety. Its lightweight design and portable packaging make it easy to handle and store in various healthcare environments, with a shelf life of 2-3 years when stored properly.

FAQ's of ERCP Biliary Flow Stent 10 mm 100 mm:


Q: How is the ERCP Biliary Flow Stent used in clinical practice?

A: The stent is introduced endoscopically during an ERCP procedure to maintain biliary duct patency and facilitate bile drainage in patients suffering from biliary obstruction. Its design allows for smooth and atraumatic insertion.

Q: What are the benefits of the stent's flared ends and side holes?

A: Flared ends help prevent the stent from migrating out of position, while the side holes enhance bile drainage efficiency and minimize the risk of occlusion in the stented duct.

Q: When should this biliary stent be considered for patient care?

A: This stent is indicated for use in adult and pediatric patients with biliary disorders requiring drainage, such as strictures or obstructions, and is suitable for hospital, clinic, or endoscopy center settings.

Q: Where should the ERCP Biliary Flow Stent be stored before use?

A: The stent should be kept in its original sterile blister pack and stored in a cool, dry place, protected from direct sunlight to maintain its sterility and integrity.

Q: What is the process for placing this stent?

A: The stent is placed under endoscopic and fluoroscopic guidance. Its radiopaque stripes ensure accurate placement by making the stent clearly visible on X-ray imaging during the procedure.

Q: Is the stent reusable, and what are its disposability instructions?

A: No, the stent is strictly single-use and disposable. After the procedure, it should be disposed of according to medical waste protocols to prevent cross-contamination.

Q: What advantages does the medical-grade polymer provide for this stent?

A: The material ensures flexibility, kink resistance, and a smooth, non-irritating surface-contributing to patient comfort and reducing the risk of complications during biliary drainage procedures.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Gastrology Products Category

endoscopic stent introducer kit - 8.5 fr

endoscopic stent introducer kit - 8.5 fr

Price 6 USD ($) / Piece

Minimum Order Quantity : 1 Piece

Condition : New

Wall Mounted : No

Technology : Endoscopic guidewire facilitation

Material : Other, Medical Grade Plastic and Stainless Steel

ERCP Aspiration Needle for Biliary Drain 19 G

ERCP Aspiration Needle for Biliary Drain 19 G

Price 6 USD ($) / Piece

Minimum Order Quantity : 1 Piece

Condition : New

Wall Mounted : No

Technology : Endoscopic; Aspiration Needle Technology

Material : Other, Stainless Steel, Medical Grade Plastic

Gastric Balloon Deflation Devices

Gastric Balloon Deflation Devices

Price 6 USD ($) / Piece

Minimum Order Quantity : 1 Piece

Condition : New

Wall Mounted : No

Technology : Manual Mechanical Deflation

Material : Other, Medical Grade Polymer and Stainless Steel

Hepatic Duct Flow Stent Double Pigtail 8.5 Fr

Hepatic Duct Flow Stent Double Pigtail 8.5 Fr

Price 6 USD ($) / Piece

Minimum Order Quantity : 1 Piece

Condition : New

Wall Mounted : No

Technology : Catheter Based Implantation

Material : Other, Medical Grade Polyurethane



Back to top