Esophageal Uncovered SEMS for Stricture Relief - 18x120 mm
Esophageal Uncovered SEMS for Stricture Relief - 18x120 mm
Esophageal Uncovered SEMS for Stricture Relief - 18x120 mm
Esophageal Uncovered SEMS for Stricture Relief - 18x120 mm
Esophageal Uncovered SEMS for Stricture Relief - 18x120 mm
Esophageal Uncovered SEMS for Stricture Relief - 18x120 mm
Esophageal Uncovered SEMS for Stricture Relief - 18x120 mm
Esophageal Uncovered SEMS for Stricture Relief - 18x120 mm
Esophageal Uncovered SEMS for Stricture Relief - 18x120 mm
Esophageal Uncovered SEMS for Stricture Relief - 18x120 mm
Esophageal Uncovered SEMS for Stricture Relief - 18x120 mm
Esophageal Uncovered SEMS for Stricture Relief - 18x120 mm

Esophageal Uncovered SEMS for Stricture Relief - 18x120 mm

Price 6 USD ($)/ Piece

MOQ : 1 Piece

Esophageal Uncovered SEMS for Stricture Relief - 18x120 mm Specification

  • Instruments Type
  • Minimally invasive medical device
  • Measurement Range
  • 18 mm diameter, 120 mm usable length
  • Accuracy
  • High, conforms closely to esophageal walls
  • Shelf Life
  • Up to 3 years (unopened, as per manufacturers instruction)
  • Storage Instructions
  • Store in a cool, dry place away from direct sunlight
  • Function
  • Esophageal stricture relief, maintains patency
  • Usage Type
  • Single Use Only
  • Features
  • Excellent radial force, precise placement, fully uncovered, anti-migration design
  • Equipment Type
  • Esophageal Uncovered Self-Expandable Metal Stent (SEMS)
  • Material
  • Nitinol (Nickel Titanium Alloy)
  • Condition
  • New
  • Technology
  • Self-expandable Memory Alloy Technology
  • Portable
  • Yes
  • Wall Mounted
  • No
  • Real-Time Operation
  • Yes
  • Noise Level
  • Silent operation
  • Operating Type
  • Manual Deployment
  • Use
  • Stricture Relief for Esophageal Obstruction
  • Dimension (L*W*H)
  • 18 mm diameter x 120 mm length
  • Weight
  • Lightweight (Precise value depends on stent dimensions)
  • Color
  • Metallic Silver
  • Latex Content
  • Latex-free
  • Packaging
  • Individually packed in sterile peel-open packs
  • Deployment System
  • Introduction system included for controlled release
  • Removal
  • Removable by endoscopic procedure when indicated
  • Flexibility
  • High conformability for tortuous anatomy
  • Patient Safety
  • Atraumatic rounded stent ends minimize tissue injury
  • Radiopacity
  • Radiopaque markers for accurate positioning under fluoroscopy
  • Indication
  • Benign and malignant esophageal strictures
  • Compatibility
  • Fits standard endoscope delivery systems
  • Corrosion Resistance
  • Excellent, suitable for long implantation periods
  • Sterilization Method
  • Sterile, provided in sealed packaging
 
 

About Esophageal Uncovered SEMS for Stricture Relief - 18x120 mm

The Esophageal Uncovered SEMS for Stricture Relief 18120 mm is used in endoscopic treatment of esophageal strictures and obstructions that restrict swallowing. Its self-expanding metal mesh design provides reliable and uniform lumen opening while maintaining flexibility for patient comfort. The uncovered configuration promotes tissue integration, offering strong anchorage and reducing the chances of stent migration during therapy. Radiopaque markers improve visibility under imaging, ensuring precise endoscopic placement. Advin Health Care supplies this stent with dependable quality suitable for advanced gastrointestinal and esophageal interventions.


Advanced Features:

  • Uncovered design for secure tissue integration

  • Self-expanding metal mesh for smooth deployment

  • Flexible construction for improved patient comfort

  • Radiopaque markers for accurate placement



Advanced Radiopaque Guided Placement

Radiopaque markers are integrated into the stent, enabling accurate visualization and positioning under fluoroscopy during the procedure. This ensures precise alignment at the site of esophageal obstruction, reducing the risk of misplacement and facilitating a smooth clinical workflow for physicians performing minimally invasive interventions.


Engineered for Flexibility and Patient Safety

With high conformability, this stent adapts effortlessly to irregular esophageal contours and tortuous anatomical pathways. The atraumatic rounded ends further ensure minimal risk of tissue injury or discomfort, providing safe, effective, and gentle stricture relief for both benign and malignant esophageal conditions.


Fully Compatible and Convenient for Clinical Use

Supplied sterile in individually peel-open packs, this lightweight stent is designed for use with standard endoscope delivery systems. Its anti-migration and corrosion-resistant properties allow for prolonged implantation, while endoscopic removability supports tailored patient care. The single-use device streamlines handling and reduces infection risks.

FAQ's of Esophageal Uncovered SEMS for Stricture Relief - 18x120 mm:


Q: How is the Esophageal Uncovered SEMS positioned during the procedure?

A: The stent is equipped with radiopaque markers to help physicians achieve accurate placement under fluoroscopy. It is deployed through an integrated introduction system, ensuring precise and controlled release at the targeted site.

Q: What are the primary uses for this stent?

A: This SEMS is indicated for relieving strictures of the esophagus, whether benign or malignant. It is effective in restoring patency and improving swallowing for patients with obstructive esophageal conditions.

Q: When should the stent be removed, and how is this done?

A: The stent may be removed by a physician using an endoscopic procedure when clinically indicated, such as upon resolution of the stricture or when repositioning is necessary. Removal is minimally invasive and typically well tolerated.

Q: Where should the stent be stored prior to use?

A: The unopened stent should be stored in a cool, dry place away from direct sunlight to maintain its sterility and integrity. The packaging is sterile and designed for single-use only.

Q: What benefits does the nitinol construction provide?

A: Nitinol offers excellent corrosion resistance and self-expandable memory alloy properties, allowing the stent to conform closely to the esophageal walls and maintain radial force, supporting long implantation periods and reliable patency.

Q: How does the stent ensure patient safety during and after placement?

A: Its atraumatic, rounded ends are designed to minimize tissue injury, while its anti-migration design helps prevent displacement. The stent is also latex-free, reducing the risk of allergic reactions.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Gastrology Products Category

ERCP Long Nose Sphincterotome - Double Lumen - 20 mm

ERCP Long Nose Sphincterotome - Double Lumen - 20 mm

Price 6 USD ($) / Piece

Minimum Order Quantity : 1 Piece

Operating Type : Other, Manual with Electrosurgical Compatibility

Features : Long Nose, Double Lumen, Rotatable Handle, Radiopaque Tip, Preloaded Guidewire Channel, PTFE Insulated Outer

Usage Type : Singleuse (Disposable)

Real-Time Operation : Yes

ERCP Aspiration Needle for Biliary Drain 19 G

ERCP Aspiration Needle for Biliary Drain 19 G

Price 6 USD ($) / Piece

Minimum Order Quantity : 1 Piece

Operating Type : Other, Manual, Single Use

Features : Sharp bevel tip, Ergonomic handle, Smooth plunger action, Compatible with standard endoscopes, Sterile and disposable

Usage Type : SingleUse (Disposable)

Real-Time Operation : Yes

ERCP Stone Retrieval Basket Double Lumen 2.3 mm  230 cm

ERCP Stone Retrieval Basket Double Lumen 2.3 mm 230 cm

Price 6 USD ($) / Piece

Minimum Order Quantity : 1 Piece

Operating Type : Manual

Features : Double lumen design, radiopaque markers, flexible, kink resistant

Usage Type : Hospital, clinical

Real-Time Operation : Yes

Endoscopy Foreign Body Forceps - Regular - Dromia Basket Nitinol 170 cm

Endoscopy Foreign Body Forceps - Regular - Dromia Basket Nitinol 170 cm

Price 4 USD ($) / Piece

Minimum Order Quantity : 1 Piece

Operating Type : Manual

Features : Flexible, Corrosion Resistant, Radiopaque, Reusable, High Strength, NonTraumatic Tip

Usage Type : Reusable

Real-Time Operation : Yes



Back to top