Gastroenterology Bile Duct Stent Straight  11.5 Fr
Gastroenterology Bile Duct Stent Straight  11.5 Fr
Gastroenterology Bile Duct Stent Straight  11.5 Fr
Gastroenterology Bile Duct Stent Straight  11.5 Fr
Gastroenterology Bile Duct Stent Straight  11.5 Fr
Gastroenterology Bile Duct Stent Straight  11.5 Fr
Gastroenterology Bile Duct Stent Straight  11.5 Fr
Gastroenterology Bile Duct Stent Straight  11.5 Fr
Gastroenterology Bile Duct Stent Straight  11.5 Fr
Gastroenterology Bile Duct Stent Straight  11.5 Fr
Gastroenterology Bile Duct Stent Straight  11.5 Fr
Gastroenterology Bile Duct Stent Straight  11.5 Fr

Gastroenterology Bile Duct Stent Straight 11.5 Fr

Price 6 USD ($)/ Piece

MOQ : 1 Piece

Gastroenterology Bile Duct Stent Straight 11.5 Fr Specification

  • Function
  • Facilitates biliary drainage
  • Accuracy
  • Accurate placement
  • Storage Instructions
  • Store in cool, dry place, away from direct sunlight
  • Usage Type
  • Single-use, Disposable
  • Shelf Life
  • 5 Years
  • Features
  • Radiopaque line, Smooth surface, Rounded tip for atraumatic insertion, Multiple side holes for optimal drainage
  • Instruments Type
  • Surgical Stent
  • Measurement Range
  • 11.5 Fr (diameter), 12cm (length)
  • Equipment Type
  • Gastroenterology Bile Duct Stent
  • Material
  • Medical-grade Polyurethane
  • Condition
  • New
  • Technology
  • Non-metallic stent insertion
  • Portable
  • Yes
  • Wall Mounted
  • No
  • Real-Time Operation
  • Yes
  • Noise Level
  • Silent Operation
  • Operating Type
  • Manual
  • Use
  • Endoscopic placement in bile duct
  • Dimension (L*W*H)
  • Length: 12cm, Diameter: 11.5 Fr
  • Weight
  • Approx. 1.5 g
  • Color
  • Translucent
  • Maximum Drainage Capacity
  • High flow design
  • Instructions for Use
  • Supplied with detailed procedure guide
  • Side Holes
  • Multiple side holes for enhanced bile flow
  • Insertion Method
  • Endoscopic or percutaneous
  • Intended Use
  • For temporary or permanent endoscopic drainage of biliary tract obstruction
  • Manufacturer Warranty
  • Available upon request
  • End Tip Design
  • Rounded and tapered for safe insertion
  • Radiopacity
  • Integrated radiopaque strip for visualization under fluoroscopy
  • Connector Type
  • Universal stent connector compatible
  • Packaging
  • Individually packed in sterile blister pack
  • Patient Compatibility
  • Suitable for adult biliary procedures
  • Latex Content
  • Latex-free
  • Shape
  • Straight
  • Compliance Standard
  • Meets ISO 10993 and CE Medical Device requirements
  • Sterilization
  • Gamma sterilized
 
 

About Gastroenterology Bile Duct Stent Straight 11.5 Fr

The Gastroenterology Bile Duct Stent Straight 11.5 Fr provides a reliable solution for maintaining bile flow in cases of biliary obstruction. Its larger diameter supports enhanced drainage efficiency, making it suitable for advanced clinical requirements. The straight configuration offers predictable handling, allowing clinicians to position the stent accurately during ERCP or other endoscopic interventions. Manufactured by Advin Health Care, this stent delivers dependable performance and is designed to support safe and effective biliary drainage across various gastroenterology procedures.


Advanced Features

  • Straight stent design for smooth and precise placement

  • 11.5 Fr diameter for high-capacity bile drainage

  • Biocompatible material suitable for clinical safety

  • Radiopaque design for clear visibility during positioning



Enhanced Drainage and Visualization

Designed with multiple side holes and a high flow channel, this stent ensures optimal bile drainage for patients with biliary tract obstruction. The integrated radiopaque strip allows for precise placement during fluoroscopic monitoring, providing accuracy in real-time procedures. The smooth surface and rounded tip greatly reduce the risk of trauma during insertion, supporting both patient safety and procedural efficacy.


Safe, Sterile, and Versatile

Sterilized using gamma irradiation and sealed in an individual blister pack, this bile duct stent meets stringent safety and hygiene standards. Its universal connector allows compatibility with a range of endoscopic equipment, while the detailed procedural guide supports clinicians through accurate placement. Constructed from latex-free, medical-grade polyurethane, it ensures biocompatibility and minimizes allergic risks.

FAQ's of Gastroenterology Bile Duct Stent Straight 11.5 Fr:


Q: How is the Gastroenterology Bile Duct Stent Straight 11.5 Fr typically inserted?

A: This stent is designed for endoscopic or percutaneous insertion under fluoroscopic guidance to ensure correct placement. The tapered, rounded tip and smooth surface facilitate atraumatic insertion and reduce the risk of injury to the biliary tract.

Q: What are the main benefits of using this stent for biliary drainage?

A: The stent provides enhanced bile flow thanks to multiple side holes and a high flow design. The radiopaque strip allows for clear visualization during placement, increasing procedural accuracy and patient safety. Its biocompatible, latex-free construction reduces the risk of allergic reactions.

Q: When should I use the Gastroenterology Bile Duct Stent Straight 11.5 Fr?

A: This stent is intended for temporary or permanent drainage in cases of biliary tract obstruction in adults. It is suitable for both elective and emergency endoscopic procedures requiring effective decompression of the bile duct.

Q: Where can this stent be applied within clinical practice?

A: It is intended for use in hospital gastroenterology departments, endoscopy suites, and specialized surgical centers equipped for biliary interventions, offering reliable drainage for suitable adult patients.

Q: What process should be followed to ensure correct usage of the stent?

A: Carefully follow the included detailed procedure guide. Maintain strict aseptic technique, confirm stent placement under fluoroscopy, and use the universal connector to attach the stent to compatible endoscopy equipment. Proper post-procedure monitoring ensures continued patency and drainage.

Q: What are the storage requirements for the stent before use?

A: Store the stent in a cool, dry environment away from direct sunlight. The individually packed blister seal ensures sterility until the point of use, and the stent maintains a shelf life of up to five years.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Gastrology Products Category

GI Polypectomy Snare - Crescent Shape - 230 cm

GI Polypectomy Snare - Crescent Shape - 230 cm

Price 6 USD ($) / Piece

Minimum Order Quantity : 1 Piece

Color : Blue handle, stainless steel loop

Portable : Yes

Function : Polyp excision and retrieval

Condition : New

Gastrointestinal Bile Flow Drainage Tube 11.5 Fr

Gastrointestinal Bile Flow Drainage Tube 11.5 Fr

Price 6 USD ($) / Piece

Minimum Order Quantity : 1 Piece

Color : Translucent with marked scale

Portable : Yes

Function : Facilitate bile flow/drainage

Condition : New

Endoscopic Covered Metal Esophageal Tube - 20x140 mm

Endoscopic Covered Metal Esophageal Tube - 20x140 mm

Price 6 USD ($) / Piece

Minimum Order Quantity : 1 Piece

Color : Silver (metal) with translucent polymer cover

Portable : Yes, for clinical use

Function : Restores esophageal patency and allows food passage

Condition : New

Hepatic Duct Drainage Catheter Straight  8.5 Fr

Hepatic Duct Drainage Catheter Straight 8.5 Fr

Price 6 USD ($) / Piece

Minimum Order Quantity : 1 Piece

Color : Transparent or radiopaque

Portable : Yes

Function : To enable external drainage of the hepatic duct

Condition : New



Back to top