Gastroenterology Covered Esophageal Stent Device - 18x120 mm
Gastroenterology Covered Esophageal Stent Device - 18x120 mm
Gastroenterology Covered Esophageal Stent Device - 18x120 mm
Gastroenterology Covered Esophageal Stent Device - 18x120 mm
Gastroenterology Covered Esophageal Stent Device - 18x120 mm
Gastroenterology Covered Esophageal Stent Device - 18x120 mm
Gastroenterology Covered Esophageal Stent Device - 18x120 mm
Gastroenterology Covered Esophageal Stent Device - 18x120 mm
Gastroenterology Covered Esophageal Stent Device - 18x120 mm
Gastroenterology Covered Esophageal Stent Device - 18x120 mm
Gastroenterology Covered Esophageal Stent Device - 18x120 mm
Gastroenterology Covered Esophageal Stent Device - 18x120 mm
Gastroenterology Covered Esophageal Stent Device - 18x120 mm
Gastroenterology Covered Esophageal Stent Device - 18x120 mm

Gastroenterology Covered Esophageal Stent Device - 18x120 mm

Price 6 USD ($)/ Piece

MOQ : 1 Piece

Gastroenterology Covered Esophageal Stent Device - 18x120 mm Specification

  • Storage Instructions
  • Store in a dry, cool place, away from direct sunlight
  • Instruments Type
  • Gastroenterology intervention device
  • Usage Type
  • Single-use
  • Function
  • Restores patency in obstructed esophagus, prevents tumor ingrowth
  • Shelf Life
  • 3 years
  • Features
  • Radiopaque markers, fully covered, anti-migration design, flexible, corrosion resistant
  • Accuracy
  • Device adapts to anatomical variations precisely
  • Measurement Range
  • 18 mm diameter, 120 mm length
  • Equipment Type
  • Covered Esophageal Stent Device
  • Material
  • Nitinol with biocompatible polymer covering
  • Condition
  • New
  • Technology
  • Self-expanding mesh design
  • Portable
  • Yes
  • Wall Mounted
  • No
  • Real-Time Operation
  • Yes
  • Noise Level
  • Silent operation
  • Operating Type
  • Manual deployment with endoscopic guidance
  • Use
  • Esophageal strictures, malignant obstructions, palliative treatment
  • Power Source
  • Not required (manual)
  • Dimension (L*W*H)
  • 18 mm diameter x 120 mm length
  • Weight
  • Approx. 15-25 grams
  • Color
  • Metallic with translucent covering
  • Regulatory Compliance
  • Meets required medical safety standards
  • Latex Free
  • Yes
  • Compatibility
  • Compatible with standard endoscopic delivery systems
  • Sterilization
  • Pre-sterilized, ready to use
  • Intended Patient
  • Adults with esophageal obstruction
  • Packaging
  • Individually packed in sterile pouch
  • Expansion Mechanism
  • Self-expanding Nitinol alloy
  • Radiopacity
  • Integrated radiopaque markers for fluoroscopic confirmation
  • Repositionability
  • Non-repositionable after full deployment
  • Deployment System
  • Through the scope (TTS)
 
 

About Gastroenterology Covered Esophageal Stent Device - 18x120 mm

The Gastroenterology Covered Esophageal Stent Device 18120 mm is designed for the management of esophageal strictures, obstructions, and related conditions that affect swallowing. Its self-expanding metal framework ensures reliable opening of the esophageal lumen while maintaining flexibility for patient comfort. The full covering minimizes the risk of tissue ingrowth, making the device suitable for both short-term and extended therapeutic use. Radiopaque markers assist in precise positioning during endoscopic placement, enhancing procedural safety. Advin Health Care provides this stent with dependable quality tailored for gastroenterology and advanced endoscopic treatments.


Advanced Features:

  • Fully covered design to minimize tissue ingrowth

  • Self-expandable structure for controlled deployment

  • Flexible construction for improved patient comfort

  • Radiopaque markers for accurate visualization during placement



Advanced Design for Effective Obstruction Relief

Utilizing a self-expanding nitinol mesh, the stent securely adapts to esophageal contours, maintaining lumen patency and preventing tumor ingrowth. The fully covered, anti-migration design ensures stability while alleviating obstruction, providing a significant improvement in patient comfort and quality of life.


Pre-Sterilized and Ready for Immediate Use

Each device is individually packed in a sterile pouch and requires no additional preparation before use. Its latex-free composition minimizes allergic risks, and the packaging ensures maximal barrier protection until the point of intervention.


Precision Deployment with Radiopaque Markers

Integrated radiopaque markers enable clear fluoroscopic confirmation of stent placement, enhancing procedural accuracy. The device's through-the-scope (TTS) delivery system ensures compatibility with standard endoscopic equipment, streamlining clinical workflow.

FAQ's of Gastroenterology Covered Esophageal Stent Device - 18x120 mm:


Q: How is the covered esophageal stent device deployed?

A: The stent is deployed manually via an endoscopic procedure using a through-the-scope (TTS) deployment system. It is positioned under direct visualization and fluoroscopic guidance to ensure precise placement.

Q: What are the main indications for using this esophageal stent?

A: This device is intended for adult patients experiencing esophageal obstructions, such as strictures or malignant tumors, and is commonly used for palliation and restoration of esophageal patency.

Q: When should the stent be used during patient care?

A: The stent is utilized when patients present with significant esophageal obstruction that impedes swallowing and when less invasive treatments are insufficient or not applicable.

Q: Where should the covered esophageal stent device be stored before use?

A: It should be stored in a cool, dry place away from direct sunlight to maintain its sterility and integrity until ready for use.

Q: What process ensures accurate placement of the stent?

A: Fluoroscopic imaging, aided by the device's integrated radiopaque markers, allows clinicians to confirm and optimize stent positioning in real time during endoscopic deployment.

Q: What are the benefits of the self-expanding nitinol design?

A: The nitinol mesh provides excellent flexibility, shape memory, and gentle continuous expansion, adapting precisely to the esophageal anatomy while minimizing the risk of migration and injury.

Q: Is the device reusable or intended for single use?

A: This esophageal stent is designed for single-use only, eliminating the risk of cross-contamination and ensuring safety for each patient.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Gastrology Products Category

Endoscopy Hot Biopsy Forceps - Without Spike - 2.8 mm - 230 cm

Endoscopy Hot Biopsy Forceps - Without Spike - 2.8 mm - 230 cm

Price 4 USD ($) / Piece

Minimum Order Quantity : 1 Piece

Storage Instructions : Store in a cool, dry place away from direct sunlight

Instruments Type : Endoscopic Instrument

Material : Other, Stainless Steel

Color : Metallic Silver

Hepatic Duct Flow Stent Pancreatic  8.5 Fr

Hepatic Duct Flow Stent Pancreatic 8.5 Fr

Price 5 USD ($) / Piece

Minimum Order Quantity : 1 Piece

Storage Instructions : Store in a cool, dry place, away from direct sunlight

Instruments Type : Surgical Stent

Material : Other, Medicalgrade Polyurethane

Color : Blue (as per product image)

endoscopic stent introducer kit - 8.5 fr

endoscopic stent introducer kit - 8.5 fr

Price 6 USD ($) / Piece

Minimum Order Quantity : 1 Piece

Storage Instructions : Store in cool, dry place away from direct sunlight

Instruments Type : Endoscopic Stent Introducer

Material : Other, Medical Grade Plastic and Stainless Steel

Color : Transparent/White

flexible NJ feeding tube 14 Fr x 200 cm

flexible NJ feeding tube 14 Fr x 200 cm

Price 6 USD ($) / Piece

Minimum Order Quantity : 1 Piece

Storage Instructions : Store in Cool, Dry Place, Away from Direct Sunlight

Instruments Type : Gastrointestinal Feeding Tube

Material : Other, Medical Grade Polyurethane

Color : Translucent with Markings



Back to top