Hemostasis Sheath
Hemostasis Sheath
Hemostasis Sheath
Hemostasis Sheath
Hemostasis Sheath
Hemostasis Sheath
Hemostasis Sheath
Hemostasis Sheath

Hemostasis Sheath

Price 6 USD ($)/ Piece

MOQ : 1 Piece

Hemostasis Sheath Specification

  • Instruments Type
  • Interventional & Surgical Access
  • Shelf Life
  • 3 years from manufacture
  • Measurement Range
  • Available in sheath sizes from 4Fr to 11Fr
  • Features
  • Hemostasis Valve, Radiopaque Markings, Smooth Dilator, Kink Resistant
  • Storage Instructions
  • Store in dry, cool place below 40C
  • Usage Type
  • Disposable
  • Function
  • Facilitates safe and bloodless catheter entry
  • Accuracy
  • Precise fit and leak-free performance
  • Equipment Type
  • Hemostasis Sheath
  • Material
  • Medical Grade Polyurethane (PU) and Polycarbonate
  • Condition
  • Sterile, Single Use
  • Technology
  • Hydrophilic Coated Sheath with hemostatic valve
  • Portable
  • Yes
  • Wall Mounted
  • No
  • Real-Time Operation
  • Yes (for vascular access)
  • Noise Level
  • Silent Operation
  • Operating Type
  • Manual
  • Use
  • Vascular Access, Catheter Introductions
  • Dimension (L*W*H)
  • Varied sizes available (4F-11F)
  • Weight
  • Lightweight (individual unit approx. 10g)
  • Color
  • Translucent or color-coded hub
  • Sterilization Method
  • Ethylene Oxide (EO) sterilized
  • Guidewire Compatibility
  • 0.035'' and 0.038'' (or as specified)
  • Lubrication
  • Hydrophilic for smooth insertion
  • Connector
  • Luer lock side port for flushing
  • Tip Design
  • Soft, atraumatic tapered tip
  • Packaging
  • Individual sterile pouch
  • Regulatory Certification
  • CE Marked, ISO 13485 Certified
  • Radiopacity
  • Radiopaque marker for fluoroscopic visualization
  • Hub Type
  • Ergonomic grip, color-coded
  • Latex Content
  • Latex free
  • Sheath Lengths
  • 10cm, 15cm, and 25cm options
 
 

About Hemostasis Sheath

Advin Health Care Hemostasis Sheath is designed to provide secure vascular access while maintaining effective hemostasis during interventional and diagnostic procedures. It ensures smooth device insertion and minimizes blood loss, supporting safe and controlled performance in both coronary and peripheral interventions.

Key Features

  • Integrated hemostatic valve for blood loss control
  • Smooth and atraumatic insertion
  • Provides stable access for device introduction
  • Flexible and kink-resistant sheath design
  • Ensures secure and leak-proof performance
  • Radiopaque marker for precise positioning
  • Compatible with standard interventional systems
  • Sterile and ready-to-use

Specifications

  • Type: Hemostasis Sheath
  • Application: Vascular access with hemostasis control
  • Material: Medical-grade polymer
  • Valve Type: Hemostatic valve
  • Sterilization: EO Sterilized
  • Usage: Single-use / Disposable

Certifications
CE, ISO 13485, ISO 9001 Certified

Product Keywords
Hemostasis Sheath, Hemostatic Introducer Sheath, Vascular Access Sheath, Blood Control Sheath, Interventional Sheath Device



, , , , .

Vaina hemosttica, vaina introductora hemosttica, vaina de acceso vascular, vaina de control sanguneo, dispositivo de vaina intervencionista

Gaine d'hmostase, gaine d'introduction hmostatique, gaine d'accs vasculaire, gaine de contrle sanguin, dispositif de gaine interventionnelle



Advanced Hemostatic Safety

The device integrates a high-quality hemostatic valve, ensuring effective control of blood flow and minimizing blood loss during catheter introduction. This enhances both patient safety and procedural efficiency, supporting reliable vascular access in interventional and surgical procedures.


Precision and Compatibility

Designed for compatibility with 0.035" and 0.038" guidewires, the sheath offers a precise, leak-free fit. The smooth hydrophilic coating and kink-resistant structure make insertion and manipulation effortless, reducing the risk of vessel trauma. Multiple length and size options ensure optimal results for diverse clinical indications.


Ergonomic and User-Friendly Design

Featuring an ergonomic, color-coded hub and a radiopaque marker for fluoroscopic visualization, this sheath simplifies handling and identification. The soft, atraumatic tapered tip and lightweight design further promote patient comfort and smooth passage during procedures.

FAQ's of Hemostasis Sheath:


Q: How is the Hemostasis Sheath packaged and kept sterile?

A: Each Hemostasis Sheath is individually packaged in a sterile pouch and is sterilized using Ethylene Oxide (EO) to ensure patient safety. This sterile, single-use device is ready for immediate use in clinical settings.

Q: What guidewire sizes are compatible with this sheath?

A: The sheath is compatible with 0.035" and 0.038" guidewires, or as otherwise specified. This compatibility facilitates a range of vascular and interventional procedures requiring these commonly used wire sizes.

Q: Where can this hemostasis sheath be used in medical practice?

A: The sheath is designed for use in hospitals, clinics, and any setting requiring vascular access and catheter introductions, particularly in interventional and surgical procedures. Its CE Mark and ISO certification assure quality for global applications.

Q: What process should be followed for storage and handling of the sheath?

A: Store the sheath in a dry, cool place below 40C. It should remain in its original sterile packaging until immediately before use, and only be used by trained medical professionals to maintain sterility and safety standards.

Q: How does the hydrophilic coating and atraumatic tip benefit patients and clinicians?

A: The hydrophilic coating, combined with the soft, atraumatic tapered tip, allows for smooth insertion and minimizes vessel trauma or discomfort, enhancing procedural success and patient comfort.

Q: When is it appropriate to use this sheath, and is it reusable?

A: This sheath is intended for single-use applications, particularly during vascular access and catheter insertion procedures. It is not reusable; dispose of it safely after one use in accordance with clinical guidelines.

Q: What are the main advantages of using this Hemostasis Sheath over traditional introducers?

A: Beyond precise and leak-free performance, the sheath offers silent operation, kink resistance, radiopaque visualization, a hemostatic valve for blood control, and an ergonomic color-coded grip, combining ease of use with advanced safety features.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Cardiology Products Category

Pressure Transducer Set

Pressure Transducer Set

Price 7.28 USD ($) / Piece

Minimum Order Quantity : 1 Piece

Real-Time Operation : Yes

Color : Transparent/Blue/White

Technology : MEMS (MicroElectroMechanical Systems) Sensor Technology

Storage Instructions : Store in a clean, dry, cool, and shaded location

Hemostatic Angioplasty Torque Devices, Y-Adapters, and Accessory Kits

Hemostatic Angioplasty Torque Devices, Y-Adapters, and Accessory Kits

Price 6.00 USD ($) / Piece

Minimum Order Quantity : 1 Piece

Real-Time Operation : Yes

Color : Transparent and Blue (adapter), Metallic (device)

Technology : Mechanical Torque System with Hemostatic Valve

Storage Instructions : Store in cool, dry conditions, avoid direct sunlight

Cath Lab Angiography Kit

Cath Lab Angiography Kit

Price 75 USD ($) / Set

Minimum Order Quantity : 1 Set

Real-Time Operation : Other, Yes (Supports RealTime Imaging in Cath Lab)

Color : Transparent & Blue Components

Technology : Single Use Sterile Kit for Angiography Procedures

Storage Instructions : Store in Cool, Dry Place Away from Direct Sunlight

Surgical Skin Stapler

Surgical Skin Stapler

Price 3.5 USD ($) / Piece

Minimum Order Quantity : 1 Piece

Real-Time Operation : Yes, Yes

Color : White/Blue

Technology : Manual Stapling Mechanism

Storage Instructions : Store in cool, dry place, away from direct sunlight



Back to top