High-Flow Clot Extraction Device
High-Flow Clot Extraction Device
High-Flow Clot Extraction Device
High-Flow Clot Extraction Device
High-Flow Clot Extraction Device
High-Flow Clot Extraction Device
High-Flow Clot Extraction Device
High-Flow Clot Extraction Device
High-Flow Clot Extraction Device
High-Flow Clot Extraction Device

High-Flow Clot Extraction Device

Price 210 USD ($)/ Piece

MOQ : 1 Piece

High-Flow Clot Extraction Device Specification

  • Shelf Life
  • 3 Years
  • Measurement Range
  • Suitable for 2-8mm clot size
  • Features
  • Flexible shaft, High-flow lumen, Radiopaque markers, Kink-resistant design
  • Usage Type
  • Single Use (Disposable)
  • Instruments Type
  • Interventional Medical Device
  • Storage Instructions
  • Store in a cool, dry place; keep away from direct sunlight
  • Accuracy
  • High extraction efficiency (>90%)
  • Function
  • Mechanical clot retrieval via aspiration
  • Equipment Type
  • Clot Extraction Device
  • Material
  • Medical Grade Polymer, Stainless Steel
  • Condition
  • New
  • Technology
  • High-Flow Aspiration
  • Portable
  • Yes
  • Wall Mounted
  • No
  • Real-Time Operation
  • Yes
  • Noise Level
  • Low (Below 55 dB)
  • Operating Type
  • Manual / Catheter-Based
  • Use
  • Clot Removal in Vascular Procedures
  • Power Source
  • Manual / External Aspiration System
  • Dimension (L*W*H)
  • Varies by model (Typically 110cm length, 6-8F diameter)
  • Weight
  • Approximately 50-150g (device only)
  • Color
  • Transparent with color-coded markers
  • Aspiration Lumen Diameter
  • 2.1 mm - 2.7 mm (varies by size)
  • Packaging
  • Individually packed, sterile pouch
  • Storage Temperature
  • 10C to 30C
  • Sterility
  • Sterile, EO gas sterilized
  • Operation Environment
  • Operating Room / Catheterization Lab
  • Intended Patient Population
  • Adults and pediatric use under clinician supervision
  • Manufacturer Warranty
  • 1 year (device integrity prior to use)
  • Catheter Size
  • 6F, 7F, 8F available
  • Tip Design
  • Soft, atraumatic tip for vessel safety
  • Guidewire Compatibility
  • Compatible with 0.035" guidewire
  • Compatibility
  • Compatible with standard aspiration syringes and accessories
  • Regulatory Certification
  • CE Marked, ISO 13485 compliant
  • Radiopacity
  • Full-length radiopaque markers for fluoroscopic guidance
  • Latex Free
  • Yes
 
 

High-Flow Clot Extraction Device About

The high-flow clot extraction device is designed to support effective thrombus removal by allowing enhanced aspiration during interventional treatments. Its design helps clinicians manage clot burden while maintaining controlled navigation within the vessel. Advin Health Care integrates safety-focused design and consistent performance standards into this device for dependable clinical use. The device is suitable for a range of vascular and cardiovascular procedures where efficient clot extraction is required, supporting smoother procedural workflow and reliable outcomes.

Advanced Features

  • High-flow aspiration design for effective clot removal

  • Supports rapid clearance of occluded vessels

  • Smooth construction for safe intravascular navigation

  • Compatible with standard interventional aspiration systems

Product Keywords


High-Flow Clot Extraction Device, Thrombectomy Device, Aspiration Clot Removal Device, Vascular Clot Extraction System, Interventional Thrombus Removal Device, High Flow Aspiration Catheter

U2 3a UUa 1UU Ua UU U2 3aU U U2 U UUa U U 3a UUa UU1U U2 2U U Ua UU U3 U 1UU Ua UU

NNN341NN234 N 2NN34o3434N34N12341 NoNNNoN NN3414342, NNNN341NN234 N NN3414NoN3414 , NNNN341NN234 N N NN 34121234334 N 12 N NN3414342, N NN14 N NoNNNoN NN3414342 N34NN 342, NNNN341NN234 N 12NN212N 34121234334 N 12 N NN3414342, 2NN34o3434N34N12N1 N NN 341212N1 oNNN

Dispositivo de extracciA3n de coAgulos de alto flujo, dispositivo de trombectomAa, dispositivo de aspiraciA3n para la eliminaciA3n de coAgulos, sistema de extracciA3n de coAgulos vasculares, dispositivo de eliminaciA3n de trombos intervencionista, catAter de aspiraciA3n de alto flujo

Dispositif d'extraction de caillots A haut dAbit, dispositif de thrombectomie, dispositif d'aspiration de caillots, systA me d'extraction de caillots vasculaires, dispositif d'Alimination de thrombus interventionnel, cathAter d'aspiration A haut dAbit

Engineered for High-Efficiency Clot Removal

This high-flow clot extraction device is meticulously designed for superior clot retrieval in both adult and pediatric patients. Its aspiration lumen and soft, atraumatic tip allow for safe and efficient removal of vascular clots, while the kink-resistant, flexible shaft enhances navigation across challenging anatomies. Radiopaque markers along the entire catheter promote real-time fluoroscopic visualization, ensuring accuracy during complex interventional procedures.


Versatile Compatibility and Safe Operation

Compatible with 0.035" guidewires, standard aspiration syringes, and external aspiration systems, this device is optimized for seamless integration within your current workflow. Available in multiple catheter sizes, it is suitable for a variety of vascular procedures and can be used in both operating rooms and catheter labs. The device design maximizes procedural safety with latex-free materials and a sterile, disposable construction.

FAQ's of High-Flow Clot Extraction Device:


Q: How is the High-Flow Clot Extraction Device used during a procedure?

A: The device is introduced over a 0.035" guidewire and advanced to the clot location under fluoroscopic guidance using its radiopaque markers. Aspiration of the clot is performed manually or with an external aspiration system through the high-flow lumen, ensuring efficient clot retrieval with minimal trauma.

Q: What types of clots and patient populations is the device suitable for?

A: This device is engineered for mechanical aspiration of clots ranging from 2mm to 8mm, making it suitable for a variety of vascular procedures. It is indicated for use in both adult and pediatric patients under clinical supervision.

Q: When should this clot extraction device be chosen over other options?

A: The device is ideal when high extraction efficiency, safety, and compatibility with standard interventional tools are required-especially for procedures needing real-time visualization, flexible navigation, and minimal vessel trauma.

Q: Where can the device be used?

A: It is designed for use in controlled clinical environments such as operating rooms and catheterization laboratories, providing versatility for hospital and specialized procedural settings.

Q: What sets this clot extraction device apart from other similar products?

A: Key differentiators include its high-flow aspiration lumen, flexible and kink-resistant design, complete radiopaque markers for precise positioning, and a soft atraumatic tip for improved vessel safety. It also meets stringent regulatory certifications and provides over 90% extraction efficiency.

Q: Is the device compatible with all standard accessories and aspiration equipment?

A: Yes, it is compatible with 0.035" guidewires, standard aspiration syringes, and most external aspiration systems, allowing for easy incorporation into existing clinical protocols.

Q: How should the device be stored and handled before use?

A: The device should be stored in a cool, dry place (10C to 30C) away from direct sunlight and only opened from its sterile pouch immediately prior to use to maintain sterility and integrity.

Tell us about your requirement
product

Price:  

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Cardiology Products Category

Interventional Cardiology Equipment

Interventional Cardiology Equipment

Price 50 USD ($) / Piece

Minimum Order Quantity : 1 Piece

Features : Sterile, Disposable, Radiopaque Markings, Ergonomic Design, Flexible, Kink Resistant

Operating Type : Other, Manual and Assisted

Usage Type : Hospital, Cath Lab, Diagnostic Center

Color : White, Blue, Transparent, Green (varies by device type)

Hydrophilic Nitinol Core Guidewires

Hydrophilic Nitinol Core Guidewires

Price 15 USD ($) / Piece

Minimum Order Quantity : 1 Piece

Features : Excellent torque control, smooth navigation, radiopaque tip, hydrophilic surface for low friction

Operating Type : Manual

Usage Type : Single use, sterile

Color : Blue or green body with radiopaque tip

Cardiac Electrical Pacing Lead

Cardiac Electrical Pacing Lead

Price 30 USD ($) / Piece

Minimum Order Quantity : 1 Piece

Features : Flexible, Kink Resistant, Nonthrombogenic, Radiopaque Markings, Soft tip to reduce cardiac trauma

Operating Type : Other, Manual/Insertion

Usage Type : Single Use (Disposable)

Color : Transparent/Green/Red (as per type/model)

Catheter Lab Contrast Set

Catheter Lab Contrast Set

Price 25 USD ($) / Set

Minimum Order Quantity : 1 Set

Features : Latex free, Leakproof connections, Userfriendly design, Compatible with most cathlab injectors, Disposable

Operating Type : Manual

Usage Type : Singleuse

Color : Transparent, blue, white (varies by component)



Back to top