Medical Pressure Transducer
Medical Pressure Transducer
Medical Pressure Transducer
Medical Pressure Transducer
Medical Pressure Transducer
Medical Pressure Transducer
Medical Pressure Transducer
Medical Pressure Transducer

Medical Pressure Transducer

Price 9.7 USD ($)/ Piece

MOQ : 1 Piece

Medical Pressure Transducer Specification

  • Usage Type
  • Single use
  • Accuracy
  • 1 mmHg within the range
  • Frequency
  • Continuous measurement
  • Display Type
  • External (Patient Monitor Display)
  • Shelf Life
  • 3 Years
  • Features
  • Sterile, Disposable, Accurate, Rapid Response
  • Instruments Type
  • Invasive Pressure Monitoring Device
  • Storage Instructions
  • Store in cool, dry place, away from sunlight
  • Function
  • Pressure measurement & electrical signal transmission
  • Measurement Range
  • -50 to +300 mmHg
  • Equipment Type
  • Medical Pressure Transducer
  • Material
  • Medical Grade Polycarbonate, Silicone, Stainless Steel
  • Condition
  • New
  • Technology
  • MEMS Sensor Technology
  • Portable
  • Yes
  • Wall Mounted
  • No
  • Real-Time Operation
  • Yes
  • Noise Level
  • Low
  • Operating Type
  • Electronic
  • Use
  • Measurement of arterial, central venous, or other physiological pressures in critical care and anesthesiology
  • Power Source
  • External (via Patient Monitor)
  • Power Consumption
  • Low
  • Voltage
  • 3V-5V (supplied by patient monitor)
  • Dimension (L*W*H)
  • Approx. 6.9 x 2.5 x 1.5 cm
  • Weight
  • Approx. 20-30g
  • Color
  • Transparent with Blue Cap & White Chamber
  • Connector Type
  • Standard Luer Lock and Electrical Connector
  • Pressure Transmission
  • Fluid-filled Diaphragm
  • Sterility
  • EO (Ethylene Oxide) Sterilized
  • Compliance Standard
  • ISO 13485, CE Certified
  • Packaging
  • Individually packed in sterile blister pack
  • Latex Content
  • Latex-free
  • Usage Environment
  • ICU, Operation Theaters, Emergency Rooms
  • Tubing Length
  • 120 cm (custom length available)
  • Compatible Monitors
  • Universal - Compatible with most patient monitors
  • Zeroing Mechanism
  • Integrated manual zeroing port
 
 

About Medical Pressure Transducer

Advin Health Care is a trusted manufacturer of Medical Pressure Transducers designed to meet international quality standards. These devices are engineered for accurate conversion of physiological pressure into electrical signals, enabling precise and continuous monitoring in critical care, ICU, and catheterization lab environments.

Key Features

  • High accuracy for reliable pressure measurement
  • Stable signal output for consistent monitoring
  • Fast response time for real-time readings
  • Compatible with standard patient monitoring systems
  • Compact, user-friendly design for easy setup

Specifications

  • Type: Medical Pressure Transducer
  • Function: Pressure-to-electrical signal conversion
  • Material: Medical-grade components
  • Sterilization: EO Sterilized / Non-sterile options available
  • Usage: Single-use / Disposable
  • Application: Invasive blood pressure (IBP), arterial, and venous pressure monitoring

Certifications
CE, ISO 13485, and ISO 9001 certified

Product Keywords
Medical Pressure Transducer, IBP Transducer, Blood Pressure Transducer, Invasive Monitoring Device, ICU Pressure Sensor



, , , , .

Transductor de presin mdica, transductor de PAI, transductor de presin arterial, dispositivo de monitorizacin invasiva, sensor de presin de UCI

Transducteur de pression mdicale, transducteur de pression artrielle invasive, capteur de pression pour soins intensifs



Universal Compatibility and Secure Connections

Purpose-built to work with most patient monitors, this pressure transducer features a Standard Luer Lock and an electrical connector for hassle-free setup. The fluid-filled diaphragm efficiently transmits physiological pressure signals, and the custom tubing length (120 cm standard) allows flexible placement in diverse care settings.


High Accuracy and Reliable Performance

Equipped with advanced MEMS sensor technology, the device ensures precise readings with an accuracy of 1 mmHg throughout its measurement range of -50 to +300 mmHg. Continuous, real-time operation and a low noise level guarantee consistent results, making it suitable for critical monitoring in ICUs and operating theaters.


Safety, Sterility, and Ease of Use

Each transducer is EO sterilized, individually blister-packed, and constructed from latex-free materials to minimize patient risk. The integrated manual zeroing port streamlines calibration, while single-use design reduces cross-contamination. Designed for user convenience and patient safety, it meets CE and ISO 13485 regulatory standards.

FAQ's of Medical Pressure Transducer:


Q: How does the Medical Pressure Transducer measure physiological pressures?

A: The device uses a fluid-filled diaphragm connected via a Standard Luer Lock to the patient's vascular system. Changes in pressure are transmitted through the diaphragm, which is detected by the integrated MEMS sensor and converted into precise electrical signals. These signals are then relayed to a compatible patient monitor for real-time display and analysis.

Q: What types of physiological pressures can this transducer measure?

A: It is suitable for invasive monitoring of arterial, central venous, or other physiological pressures, particularly in environments such as ICUs, emergency rooms, and operation theaters.

Q: When should the integrated manual zeroing port be used?

A: The manual zeroing port should be used prior to initiating pressure measurements to calibrate the transducer and ensure the most accurate readings. Zeroing is typically performed before patient connection and whenever system accuracy is questioned during use.

Q: Where can this pressure transducer be utilized?

A: This device is designed for use in hospital critical care settings, including intensive care units, emergency departments, and operation theaters where continuous invasive pressure monitoring is required.

Q: What is the process for installing and using the transducer?

A: Begin by ensuring sterility and connecting the transducer via the Standard Luer Lock and electrical connector. Secure the tubing, perform manual zeroing using the integrated port, and link the transducer to a compatible patient monitor. The device will then provide continuous, accurate pressure measurements.

Q: What are the main benefits of using this medical pressure transducer?

A: Key advantages include high accuracy, rapid response due to MEMS technology, universal compatibility, low power consumption, sterile single-use design, latex-free construction, and compliance with international safety and quality standards.

Q: How should the transducer be stored before use?

A: Store the individually packed, sterile device in a cool, dry place away from direct sunlight. This ensures product integrity and maintains the three-year shelf life prior to use.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Cardiology Products Category

Advanced Embolic Safety Filter

Advanced Embolic Safety Filter

Price 70 USD ($) / Piece

Minimum Order Quantity : 1 Piece

Mullins Introducer Kit

Mullins Introducer Kit

Price 70 USD ($) / Piece

Minimum Order Quantity : 1 Piece

Fogarty Arterial Catheter

Fogarty Arterial Catheter

Price 30 USD ($) / Piece

Minimum Order Quantity : 1 Piece

Clot Removal Kit

Clot Removal Kit

Price 600 USD ($) / Set

Minimum Order Quantity : 1 Set



Back to top