Sirolimus-eluting coronary stents
Sirolimus-eluting coronary stents
Sirolimus-eluting coronary stents
Sirolimus-eluting coronary stents
Sirolimus-eluting coronary stents
Sirolimus-eluting coronary stents
Sirolimus-eluting coronary stents
Sirolimus-eluting coronary stents
Sirolimus-eluting coronary stents
Sirolimus-eluting coronary stents
Sirolimus-eluting coronary stents
Sirolimus-eluting coronary stents

Sirolimus-eluting coronary stents

Price 200 USD ($)/ Piece

MOQ : 1 Piece

Sirolimus-eluting coronary stents Specification

  • Features
  • Biocompatible, Flexible Design, High Radial Strength, Thin Struts
  • Storage Instructions
  • Store in a Cool, Dry Place
  • Shelf Life
  • 3 Years
  • Accuracy
  • High Placement Precision Under Angiography Guidance
  • Usage Type
  • Disposable
  • Measurement Range
  • Stent diameter: 2.5 mm to 4.0 mm; Stent length: 8 mm to 40 mm
  • Function
  • Revascularization of Blocked Coronary Arteries
  • Instruments Type
  • Implantable Medical Device
  • Equipment Type
  • Coronary Stent
  • Material
  • Cobalt Chromium Alloy
  • Condition
  • New, Sterile
  • Technology
  • Sirolimus-Eluting Drug Coated
  • Portable
  • Yes, Single-use Packaging
  • Wall Mounted
  • No
  • Real-Time Operation
  • Yes
  • Noise Level
  • Silent
  • Operating Type
  • Manual Deployment
  • Use
  • Interventional Cardiology - Treatment of Coronary Artery Disease
  • Dimension (L*W*H)
  • Stent diameter: 2.5-4.0 mm, Length: 8-40 mm (varies by model)
  • Weight
  • Lightweight (<1 gram per stent)
  • Color
  • Metallic Silver
  • Packaging
  • Sterile, Individual Blister Pack
  • Marker Bands
  • Radio-Opaque, Platinum-Iridium
  • Drug Release Kinetics
  • Controlled, Sustained up to 30 days
  • Expansion System
  • Balloon-Expandable
  • Crimped Delivery Diameter
  • 0.014 inch guidewire compatibility
  • Polymer Type
  • Biostable or Biodegradable Polymer Coating
  • Balloon Compatibility
  • Compatible with PTCA Balloons
  • Radiopacity
  • Excellent for Fluoroscopic Visualization
 
 

About Sirolimus-eluting coronary stents

Sirolimus-eluting coronary stents are designed to support long-term vessel patency by controlling excessive tissue growth within the artery. The controlled drug release helps improve healing while maintaining adequate blood flow to the heart muscle. Advin Health Care manufactures these stents with a strong focus on clinical reliability, safety, and consistent performance standards. These stents are widely used in interventional cardiology to support effective treatment of coronary artery disease and improve procedural outcomes.

Advanced Features


  • Sirolimus drug coating to help reduce restenosis
  • Designed for controlled and uniform drug release

  • Supports optimal vessel support after implantation

  • Compatible with standard coronary stent delivery systems

Certifications

We are certified with CE, ISO 13485, and ISO 9001 standards.

Product Keywords

Sirolimus-Eluting Coronary Stents, Drug-Eluting Stent (DES), Coronary Artery Stent, Anti-Restenosis Stent, Interventional Cardiology

U 1Ua UaU UUUU UU3UUUUUU3 U 1Ua U UU (DES) 1Ua U UU UaU 1Ua U UaUU U UU UaU UUU Ua UU

34N3412N12N NN12NN N N N34 14NN3414, NN12NN N oNNN21212N14 34oNNN 14 (DES), o34N3412N12N NNN N12N NN12NN, 12N NNN1234N NNo NN12NN, 12NN212N 341212N oN 34343 N

Stents coronarios liberadores de sirolimus, stent liberador de fArmacos (SLF), stent de arteria coronaria, stent antirreestenosis, cardiologAa intervencionista

Stents coronaires A Alution de sirolimus, stent A Alution de mAdicament (DES), stent de l'artA re coronaire, stent anti-restAnose, cardiologie interventionnelle



Superior Drug Delivery Technology

Utilizing Sirolimus and advanced polymer coatings, this coronary stent ensures a controlled and sustained drug release profile for up to 30 days. This approach minimizes restenosis risk by providing a consistent therapeutic effect directly at the arterial site, supporting enhanced vessel healing and reducing the likelihood of repeat procedures.


High Precision and Safety in Deployment

Engineered with platinum-iridium radio-opaque marker bands and excellent radiopacity, the stent provides outstanding fluoroscopic visibility. The result is high precision during angiography-guided placement, ensuring accuracy and safety even in complex coronary anatomies. Balloon-expandable technology enhances operator control during deployment.


Versatility and User-Friendly Design

Available in multiple diameters and lengths, this stent supports a broad range of clinical applications. Compatible with standard 0.014-inch guidewires and PTCA balloons, its flexible, lightweight design allows for easy maneuvering and optimal conformity to vessel walls, making it suitable for diverse patient profiles.

FAQ's of Sirolimus-eluting coronary stents:


Q: How does the sirolimus-eluting stent provide controlled drug release?

A: The stent is coated with a biostable or biodegradable polymer that allows for sustained and controlled release of sirolimus over up to 30 days. This ensures a consistent local therapeutic effect to reduce restenosis.

Q: What types of procedures is this coronary stent designed for?

A: This stent is intended for use in interventional cardiology, specifically for the revascularization of blocked coronary arteries in patients with coronary artery disease.

Q: When is the optimal time to use this Sirolimus-eluting stent during treatment?

A: The stent is deployed during a percutaneous coronary intervention (PCI) procedure, typically after a balloon angioplasty to restore proper blood flow in narrowed or blocked coronary arteries.

Q: Where can this stent be used, and what equipment is it compatible with?

A: It is utilized in catheterization laboratories and is compatible with PTCA balloons and 0.014-inch guidewires, fitting into standard interventional workflows.

Q: What is the deployment process for this device?

A: The stent is manually deployed over a guidewire and expanded with an angioplasty balloon at the lesion site. Its platinum-iridium markers provide excellent visibility to guide precise placement under fluoroscopy.

Q: What benefits does this stent offer to patients and clinicians?

A: Benefits include controlled drug release for reduced restenosis, excellent placement accuracy under angiography, superior vessel conformability due to its flexible design, and a broad range of size options to match patient anatomy.

Q: What storage and shelf life instructions should be followed for this coronary stent?

A: The stent should be stored in a cool, dry place and used before the expiration date (three years from manufacture). Each device comes in sterile, individual blister packaging for single-use applications.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Cardiology Products Category

Vascular Extraction Device

Vascular Extraction Device

Price 210 USD ($) / Piece

Minimum Order Quantity : 1 Piece

Real-Time Operation : Yes

Material : Other, Medical grade stainless steel, polymer components

Technology : Minimally invasive extraction

Usage Type : Hospital, clinic

Percutaneous Thrombus Catheter

Percutaneous Thrombus Catheter

Price 210 USD ($) / Piece

Minimum Order Quantity : 1 Piece

Real-Time Operation : Yes

Material : Other, Medical Grade Polyurethane

Technology : Percutaneous Catheterbased Thrombus Removal

Usage Type : Single Use, Disposable

Sterile Cardiology Products

Sterile Cardiology Products

Price 15 USD ($) / Piece

Minimum Order Quantity : 1 Piece

Real-Time Operation : Yes

Material : Other, Medical Grade Plastic and Stainless Steel

Technology : Sterile Processing, Advanced Manufacturing

Usage Type : Single Use, Clinical

Disposable Wound Stapler

Disposable Wound Stapler

Price 3.5 USD ($) / Piece

Minimum Order Quantity : 1 Piece

Real-Time Operation : Yes, Yes

Material : Other, Medical Grade Stainless Steel and ABS Plastic, Other, Medical Grade Stainless Steel and ABS Plastic

Technology : Manual Stapling Mechanism

Usage Type : Single Use



Back to top