Vessel Dilation Balloon Systems
Vessel Dilation Balloon Systems
Vessel Dilation Balloon Systems
Vessel Dilation Balloon Systems
Vessel Dilation Balloon Systems
Vessel Dilation Balloon Systems
Vessel Dilation Balloon Systems
Vessel Dilation Balloon Systems

Vessel Dilation Balloon Systems

Price 55 USD ($)/ Piece

MOQ : 1 Piece

Vessel Dilation Balloon Systems Specification

  • Accuracy
  • High Precision Dilation
  • Function
  • Vessel Dilatation, Plaque Compression
  • Usage Type
  • Single-use / Disposable
  • Features
  • High Trackability, Flexible Tip, Minimal Entry Profile, Radiopaque Marker
  • Storage Instructions
  • Store in Cool, Dry Place
  • Instruments Type
  • Interventional Cardiology Device
  • Shelf Life
  • 2-3 Years
  • Measurement Range
  • Balloon diameter typically 1.5mm-5.0mm
  • Equipment Type
  • Vessel Dilation Balloon System (PTCA Balloon Catheter)
  • Material
  • Medical-grade Polyurethane / Nylon / Pebax
  • Condition
  • New
  • Technology
  • Balloon Catheterization
  • Portable
  • Yes
  • Wall Mounted
  • No
  • Real-Time Operation
  • Yes
  • Noise Level
  • Silent Operation
  • Operating Type
  • Manual / Interventional
  • Use
  • Vessel Dilation / Angioplasty
  • Power Source
  • None (Manual Operation)
  • Dimension (L*W*H)
  • Varies (Length typically 140cm-150cm)
  • Weight
  • Lightweight (typically <10g)
  • Color
  • Transparent / Blue (as per image)
  • Balloon Length
  • Variety (10mm, 15mm, 20mm, etc.)
  • Intended Use
  • PTCA (Percutaneous Transluminal Coronary Angioplasty)
  • Compatible Guidewire Size
  • 0.014 inch
  • Radiopacity
  • Radiopaque markers for visibility under fluoroscopy
  • Sterility
  • Ethylene Oxide Sterilized
  • Packaging
  • Sterile Blister Pack
  • Latex Content
  • Latex-Free
  • Balloon Compliance
  • Semi-compliant / Non-compliant options
  • Connector Type
  • Luer-lock
  • Balloon Pressure
  • Rated Burst Pressure: up to 14 atm (varies)
 
 

About Vessel Dilation Balloon Systems

Advin Health Care is a trusted manufacturer of Vessel Dilation Balloon Systems designed to meet international quality standards. These systems are used in interventional cardiology and vascular procedures to dilate narrowed or obstructed vessels, restore adequate blood flow, and support effective treatment during angioplasty interventions.

Key Features

High-quality balloon for controlled and uniform vessel dilation
Excellent trackability for smooth navigation through vascular pathways
Flexible design for accessing complex and tortuous anatomy
Radiopaque markers for precise positioning under imaging guidance
Compatible with standard guide wires and angioplasty systems

Certifications

We are certified with CE, ISO 13485, and ISO 9001 standards.

Product Keywords

Vessel Dilation Balloon System, Angioplasty Balloon Catheter, Vascular Balloon Dilatation Device, PTCA Balloon System, Interventional Balloon Catheter, Coronary Balloon Expansion System



, , , , , .

Sistema de baln para dilatacin vascular, catter de baln para angioplastia, dispositivo de dilatacin vascular con baln, sistema de baln para PTCA, catter de baln intervencionista, sistema de expansin de baln coronario

Systme de dilatation vasculaire par ballonnet, cathter   ballonnet d'angioplastie, dispositif de dilatation vasculaire par ballonnet, systme de ballonnet pour angioplastie coronaire transluminale percutane (ACTP), cathter   ballonnet interventionnel, systme d'expansion coronaire par ballonnet



Enhanced Visibility with Radiopaque Markers

Vessel Dilation Balloon Systems feature distinct radiopaque markers that ensure excellent visibility under fluoroscopic imaging. This critical feature allows interventional cardiologists to accurately position the balloon during PTCA procedures, maximizing treatment precision and patient safety throughout angioplasty interventions.


Versatile Compliance and Sizing Options

Offering both semi-compliant and non-compliant balloon options, these systems provide clinicians with flexibility to match patient and lesion requirements. With a wide range of balloon diameters (1.5mm-5.0mm) and lengths (10mm, 15mm, 20mm, etc.), the device accommodates various vessel anatomies and complex scenarios, improving procedural success rates.


Optimal Safety and Sterility

Each balloon catheter is ethylene oxide sterilized and latex-free, ensuring high safety standards for patients with sensitivities or allergies. Devices are supplied in sterile blister packs for secure handling and reduced infection risks, while the robust shelf life (2-3 years) enhances inventory management for healthcare providers.

FAQ's of Vessel Dilation Balloon Systems:


Q: How should the Vessel Dilation Balloon System be prepared and used during a PTCA procedure?

A: Before use, ensure the device packaging is intact and within its shelf life, then open the sterile blister pack in a controlled environment. Load the system onto a compatible 0.014-inch guidewire, advance the catheter to the lesion site using fluoroscopy, and inflate the balloon to the recommended pressure to achieve precise vessel dilation. Follow all manufacturer instructions for optimal safety and performance.

Q: What are the benefits of choosing semi-compliant or non-compliant balloon options?

A: Semi-compliant balloons offer flexibility and adjustability for vessels that may require a gentle approach, while non-compliant balloons provide more controlled, high-pressure dilation for resistant lesions. Selecting the appropriate type allows clinicians to tailor treatment to individual vessel characteristics and procedural goals.

Q: When is it necessary to use a vessel dilation balloon catheter with radiopaque markers?

A: Radiopaque markers are essential whenever fluoroscopic visualization is required, particularly during angioplasty procedures, to ensure accurate balloon placement and vessel dilation. They enhance procedural safety and effectiveness by enabling real-time imaging of the device location within the coronary arteries.

Q: Where should Vessel Dilation Balloon Systems be stored before use?

A: Store the devices in a cool, dry place as indicated by the manufacturer, ensuring they remain sealed in their sterile blister packs until ready for use. Proper storage helps maintain device integrity and sterility.

Q: What is the process for selecting the appropriate balloon size and compliance profile?

A: Selection is based on the target vessel's diameter, lesion length, and lesion characteristics. Choose the balloon's diameter and length suited to the anatomy (commonly 1.5mm-5.0mm diameter, lengths from 10mm up). Decide between semi-compliant for flexibility and non-compliant for rigid plaque dilation as per procedural needs.

Q: Are these balloon catheters reusable or single-use?

A: These Vessel Dilation Balloon Systems are designed strictly for single-use only. Reuse is not recommended as it may compromise sterility, device integrity, and patient safety.

Q: What advantages do these balloon systems offer in terms of portability and handling during interventions?

A: These systems are lightweight (typically <10g), manually operated, and portable, allowing seamless integration into a variety of care settings. Their high trackability and flexible tips contribute to smooth navigation and precise positioning, enhancing procedural outcomes.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Cardiology Products Category

Angioplasty and Stent Placement - Heart

Angioplasty and Stent Placement - Heart

Price 120 USD ($) / Piece

Minimum Order Quantity : 1 Piece

Operating Type : Other, Manual & Assisted

Equipment Type : Angioplasty and Stent Placement System

Dimension (L*W*H) : Stent: Typically 24 mm Diameter, 1238 mm Length; Catheter Length: About 90150 cm

Wall Mounted : No

Pressure Injection Set

Pressure Injection Set

Price 25 USD ($) / Set

Minimum Order Quantity : 1 Set

Operating Type : Other, Disposable, Singleuse

Equipment Type : Pressure Injection Set

Dimension (L*W*H) : Standard: Approx. 180 cm tube length

Wall Mounted : No

Balloon Angioplasty Set

Balloon Angioplasty Set

Price 18 USD ($) / Kit

Minimum Order Quantity : 1 Kit

Operating Type : Manual

Equipment Type : Balloon Angioplasty Set

Dimension (L*W*H) : Varies by component (standard kit sizes)

Wall Mounted : No

Angiokit Push Pull

Angiokit Push Pull

Price 18 AUD ($) / Piece

Minimum Order Quantity : 1 Piece

Operating Type : Manual

Equipment Type : Angiography Kit

Dimension (L*W*H) : Standard Kit Size

Wall Mounted : No



Back to top