Drug Eluting Coronary Stents Specification

  • Accuracy
  • High Precision in Placement
  • Features
  • Coated with anti-proliferative drugs, biocompatible polymer, radiopaque markers, flexible design
  • Usage Type
  • Single Use
  • Function
  • Maintains vessel patency and releases drug to prevent restenosis
  • Instruments Type
  • Interventional Cardiology Device
  • Measurement Range
  • Stent diameters 2.5 - 4.0 mm; lengths 8 - 38 mm
  • Shelf Life
  • 2 to 3 Years
  • Storage Instructions
  • Store at room temperature, away from moisture and sunlight
  • Equipment Type
  • Drug Eluting Coronary Stent
  • Material
  • Cobalt Chromium Alloy
  • Condition
  • New
  • Technology
  • Drug Eluting Stent (DES)
  • Portable
  • Yes
  • Wall Mounted
  • No
  • Real-Time Operation
  • Yes
  • Noise Level
  • Silent
  • Operating Type
  • Manual deployment
  • Use
  • Coronary Artery Disease Treatment
  • Dimension (L*W*H)
  • Various Sizes Available (Commonly 2.5-4.0 mm diameter, 8-38 mm length)
  • Weight
  • Lightweight (Few grams)
  • Color
  • Metallic silver
  • Indication
  • Intended for use in patients with symptomatic coronary artery disease
  • Polymer Used
  • Durable or Bioabsorbable Polymer Coating
  • MRI Compatibility
  • Conditional (check specific product guidelines)
  • Compatibility
  • Compatible with 0.014 inch guidewire, standard balloon catheters
  • Radiopacity
  • Enhanced via radiopaque markers for visibility under fluoroscopy
  • Delivery System
  • Pre-mounted on balloon catheter
  • Surface Finish
  • Ultra-smooth to minimize vessel trauma
  • Flexibility
  • High for easier navigation in tortuous vessels
  • Expansion Method
  • Balloon expandable
  • Sterilization
  • Ethylene Oxide Sterilized
  • Drug Coating
  • Sirolimus/Everolimus/Paclitaxel (drug type varies as per product)
  • Thrombogenicity
  • Low (anti-thrombotic coating)
 
 

About Drug Eluting Coronary Stents

Advin Health Care offers Drug Eluting Coronary Stents (DES) designed to meet international quality standards. These advanced stents are coated with therapeutic drugs that are gradually released to prevent restenosis, ensuring long-term vessel patency and improved clinical outcomes in coronary artery disease treatment.

Key Features

  • Controlled drug release to reduce restenosis risk
  • Advanced stent design for optimal vessel support
  • Excellent flexibility and deliverability in complex lesions
  • Uniform drug coating for consistent performance
  • Biocompatible materials to enhance patient safety

Specifications

  • Type: Drug Eluting Coronary Stent (DES)
  • Material: Cobalt Chromium / Stainless Steel
  • Coating: Drug-eluting polymer coating
  • Delivery System: Balloon-expandable system
  • Sterilization: EO Sterilized
  • Usage: Single-use
  • Application: Treatment of coronary artery disease (CAD)

Certifications
CE, ISO 13485, and ISO 9001 certified

Product Keywords
Drug Eluting Stent, Coronary Stent, DES Stent, Cardiac Stent, Anti-Restenosis Stent, Angioplasty Stent

DES

, , , , ,

Stent liberador de frmacos, stent coronario, stent DES, stent cardaco, stent antirreestenosis, stent de angioplastia

Stent   lution de mdicament, stent coronaire, stent DES, stent cardiaque, stent anti-restnose, stent d'angioplastie




Superior Drug Delivery for Reduced Restenosis

Our stents employ innovative drug coatings like Sirolimus, Everolimus, or Paclitaxel, delivered through a polymer matrix. This technology targets local vascular tissue, minimizing cell overgrowth and restenosis. As the drug is steadily released, vessel patency is maintained over extended periods, providing effective, long-term results for patients with coronary artery disease.


Optimized Design for Precision and Flexibility

Engineered from cobalt chromium alloy and featuring an ultra-smooth surface, the stents offer high flexibility for navigation through tortuous vessels. Enhanced radiopacity from integrated markers ensures clear visibility under fluoroscopy, allowing for confident, accurate placement. The lightweight, portable design further simplifies handling during interventional procedures.


Safe and Compatible with Standard Procedures

The stents are compatible with standard 0.014-inch guidewires and pre-mounted on balloon catheters for single-use deployment. MRI conditional labeling and ethylene oxide sterilization provide added safety. The low-thrombogenic polymer coating and biocompatible materials make these stents a reliable choice for interventional cardiologists.

FAQ's of Drug Eluting Coronary Stents:


Q: How does a drug eluting coronary stent work in treating coronary artery disease?

A: A drug eluting coronary stent is placed inside a narrowed artery using a balloon catheter. After deployment, it maintains vessel patency while slowly releasing anti-proliferative drugs (such as Sirolimus, Everolimus, or Paclitaxel) to prevent restenosis by inhibiting excessive tissue growth within the arterial wall.

Q: What steps are followed during the placement of these stents?

A: The stent, pre-mounted on a balloon catheter and compatible with a 0.014-inch guidewire, is guided to the site of blockage. Under fluoroscopy, radiopaque markers help accurately position the stent. The balloon is then inflated to expand the stent, anchoring it within the vessel, after which the catheter is withdrawn.

Q: When should a drug eluting coronary stent be used?

A: These stents are indicated for patients with symptomatic coronary artery disease requiring intervention to restore adequate blood flow. They are particularly recommended when the risk of restenosis or vessel re-narrowing is a concern.

Q: Where should these stents be stored before use?

A: The stents should be stored at room temperature in their original packaging, away from moisture and sunlight, to preserve sterility and ensure optimal performance until their use within the 2-3 year shelf life.

Q: What compatibility features do these stents offer for interventional procedures?

A: These stents are designed for compatibility with standard 0.014-inch guidewires and balloon catheters, making them suitable for routine interventional cardiology procedures. Their balloon-expandable nature and radiopaque markers provide further ease and precision during deployment.

Q: What are the benefits of using drug eluting stents with anti-thrombotic coating?

A: The anti-thrombotic coating significantly reduces the risk of blood clot formation on the stent's surface, while the controlled drug release prevents tissue overgrowth. Together, these mechanisms lower the chances of restenosis and adverse cardiac events after the procedure.

Q: Is this stent suitable for use in patients requiring MRI?

A: The stent is conditionally MRI compatible, but users must refer to specific product guidelines to ensure safe imaging practices for patients who may require MRI scans after stent placement.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Cardiology Products Category

Extension lines with stopcocks - Vascular products

Extension lines with stopcocks - Vascular products

Price 0.40 USD ($) / Piece

Minimum Order Quantity : 1 Piece

Wall Mounted : No

Use : Intravenous Fluid Administration, Vascular Access

Condition : New

Equipment Type : Extension Line with Stopcock

Low Profile Radial Sheath

Low Profile Radial Sheath

Price 6 USD ($) / Piece

Minimum Order Quantity : 1 Piece

Wall Mounted : No

Use : Vascular Access / Cardiac Catheterization

Condition : New

Equipment Type : Radial Sheath

PTCA Kit

PTCA Kit

Price 1500 INR / Piece

Minimum Order Quantity : 1 Piece

Wall Mounted : No

Use : Hospital

Condition : New

Equipment Type : Medical Equipments

Medical Manifold Advin

Medical Manifold Advin

Price 2 USD ($) / Piece

Minimum Order Quantity : 1 Piece



Back to top