K Wire Threaded (Kirschner Wire)
K Wire Threaded (Kirschner Wire)
K Wire Threaded (Kirschner Wire)
K Wire Threaded (Kirschner Wire)
K Wire Threaded (Kirschner Wire)
K Wire Threaded (Kirschner Wire)
K Wire Threaded (Kirschner Wire)
K Wire Threaded (Kirschner Wire)
K Wire Threaded (Kirschner Wire)
K Wire Threaded (Kirschner Wire)

K Wire Threaded (Kirschner Wire)

Price 5 USD ($)/ Piece

MOQ : 1 Piece

K Wire Threaded (Kirschner Wire) Specification

  • Instruments Type
  • Orthopedic Implant
  • Storage Instructions
  • Store in a clean, dry environment. Avoid moisture and contaminants.
  • Function
  • Bone fixation in orthopedic surgery, temporary fixation, guiding surgical procedures
  • Accuracy
  • High precision manufacturing for surgical use
  • Shelf Life
  • 5 Years
  • Usage Type
  • Single Use, Disposable
  • Features
  • Threaded end for secure anchorage, corrosion resistant, sterile packaging, smooth finish
  • Measurement Range
  • Diameter typically 1.0 mm to 3.0 mm
  • Equipment Type
  • K Wire Threaded (Kirschner Wire)
  • Material
  • Stainless Steel Medical Grade
  • Condition
  • New
  • Technology
  • Threaded Orthopedic Fixation Wire
  • Portable
  • Yes
  • Wall Mounted
  • No
  • Real-Time Operation
  • Yes
  • Noise Level
  • Silent
  • Operating Type
  • Manual
  • Use
  • Orthopedic Fixation, Fracture Management
  • Dimension (L*W*H)
  • Varying diameters (commonly 1.0 mm to 3.0 mm), Length as per requirement (typically 150 mm 300 mm)
  • Weight
  • Lightweight, varies by diameter and length
  • Color
  • Metallic Silver
  • Radiopacity
  • Radiopaque for X-ray visibility
  • Surface Finish
  • Smooth, mirror finish to minimize tissue damage
  • Compatibility
  • Compatible with standard orthopedic drills and holding instruments
  • Tip Style
  • Pointed/Blunt/Trocar End
  • Compliance Standards
  • ISO 13485, CE Marked
  • Sterilization Method
  • EO (Ethylene Oxide) Sterilized
  • Thread Type
  • Partially Threaded or Fully Threaded
  • Application
  • Ideal for skeletal traction, external fixation, and intramedullary fixation
  • Reusable
  • No, single use only
  • Packaging Type
  • Sterile Pack
 
 

About K Wire Threaded (Kirschner Wire)

The K Wire Threaded (Kirschner Wire) from Advin Health Care is engineered to provide superior fixation and stability in orthopedic surgeries. The threaded design minimizes the risk of wire migration and allows secure anchoring in bone tissue. Surgeons can achieve precise fracture reduction and maintain proper alignment throughout the healing process. Lightweight and durable, it integrates seamlessly with standard orthopedic instruments for efficient surgical workflow.

Advanced Features:

  1. Threaded design for enhanced bone fixation
  2. High-quality stainless steel for strength and durability
  3. Minimizes risk of wire migration
  4. Enables precise fracture reduction and alignment
  5. Compatible with standard orthopedic instruments


Engineered for Surgical Precision

K Wire Threaded (Kirschner Wire) is designed with high accuracy and a mirror-smooth surface to minimize tissue damage. Available in various tip styles and thread types, it ensures secure bone fixation and efficient surgical techniques. Corrosion resistance and radiopacity deliver durable performance and clear X-ray visibility during procedures.


Sterile & Single-Use for Patient Safety

Each wire is individually EO (Ethylene Oxide) sterilized and packaged in sterile packs to prevent contamination. Intended for single use only, these wires eliminate cross-infection risk, meeting ISO 13485 and CE standards for quality and safety in orthopedic surgeries.


Versatile Application in Orthopedic Practice

Compatible with most orthopedic drills and standard holding instruments, the K Wire is vital for skeletal traction, external and intramedullary fixation, and guiding fracture management. Lightweight and portable, it fits diverse clinical requirements, offering flexibility for surgeons in a wide range of procedures.

FAQs of K Wire Threaded (Kirschner Wire):


Q: How should the K Wire Threaded be used during orthopedic surgeries?

A: The K Wire Threaded is inserted with standard orthopedic drills or holding instruments. Its partially or fully threaded design provides secure bone anchorage, and various tip options help adapt to specific surgical needs. It is ideal for fixation, guiding surgical procedures, or temporary skeletal traction.

Q: What sterilization method is used for these Kirschner wires?

A: The wires are sterilized with Ethylene Oxide (EO) gas, ensuring sterility while maintaining the wires structural integrity. Sterile packaging keeps the wire contaminant-free until it is ready for use.

Q: When is it appropriate to use a partially threaded versus a fully threaded K Wire?

A: Partially threaded K Wires are preferred when differential anchorage is needed, providing secure fixation at one end. Fully threaded wires are chosen for consistent grip throughout the wires length. The selection depends on the specific bone fixation and surgical requirements.

Q: Where can these K Wire Threaded wires be used?

A: These wires are suitable for hospitals, clinics, and surgical centers that perform orthopedic surgeries. They are primarily used in operating rooms for skeletal traction, external fixation, or intramedullary fixation procedures.

Q: What are the benefits of their radiopaque nature?

A: Radiopaque wires are easily visible under X-ray imaging, allowing surgeons to confirm positioning, monitor progress, and adjust placement during surgeries, enhancing precision and patient safety.

Q: How should the Kirschner wires be stored before use?

A: Store the wires in a clean, dry environment, away from moisture and contaminants to preserve sterility and prevent corrosion. Always check the packaging integrity before surgical use.

Q: Can the K Wire Threaded be reused after a procedure?

A: No, these wires are designed for single use only. Reusing disposable wires compromises sterility and can lead to infection or diminished mechanical properties, so a new sterile wire must be used for each procedure.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Orthopedic Trauma Products Category

Proximal Femoral Nail (P.F.N) (Right)

Proximal Femoral Nail (P.F.N) (Right)

Price 6 USD ($) / Piece

Minimum Order Quantity : 1 Piece

Wall Mounted : No

Dimension (L*W*H) : Custom sizes available (typically length 170420 mm)

Technology : CNC Machined, Polished

Function : Internal fixation and stabilization of proximal femur fractures

95 DCS Barrel Plate DCP Hole

95 DCS Barrel Plate DCP Hole

Price 6 USD ($) / Piece

Minimum Order Quantity : 1 Piece

Wall Mounted : No

Dimension (L*W*H) : Varies depending on bone size/application (typically 95 geometry)

Technology : Forged and Precision Machined

Function : Stabilization and fixation of bone fractures

8.0mm Proximal Femoral Screw

8.0mm Proximal Femoral Screw

Price 5 USD ($) / Piece

Minimum Order Quantity : 1 Piece

Wall Mounted : No

Dimension (L*W*H) : 8.0mm Diameter, Lengths Vary (Specify As Needed)

Technology : CNC Machined, Precision Engineered

Function : Stabilizes Proximal Femur Fractures

3.5mm Small T Locking Plates Right Angled

3.5mm Small T Locking Plates Right Angled

Price 1 USD ($) / Piece

Minimum Order Quantity : 1 Piece

Wall Mounted : No

Dimension (L*W*H) : Available Lengths: 66mm, 80mm, 96mm (Width approx. 10mm, Height approx. 3.5mm)

Technology : Locking Plate Technology

Function : Stabilizes fractured bones, Aids in bone healing



Back to top