Temporary Cardiac Pacing
Temporary Cardiac Pacing
Temporary Cardiac Pacing
Temporary Cardiac Pacing
Temporary Cardiac Pacing
Temporary Cardiac Pacing
Temporary Cardiac Pacing
Temporary Cardiac Pacing
Temporary Cardiac Pacing
Temporary Cardiac Pacing
Temporary Cardiac Pacing
Temporary Cardiac Pacing

Temporary Cardiac Pacing

Price 30 USD ($)/ Piece

MOQ : 1 Piece

Temporary Cardiac Pacing Specification

  • Usage Type
  • Hospital, Emergency, ICU
  • Features
  • Dual Chamber, Adjustable Pacing Rate and Output, Alarm Function, Display Screen, Battery Backup
  • Display Type
  • Digital LCD
  • Storage Instructions
  • Store in Cool, Dry Place
  • Accuracy
  • 1 bpm
  • Shelf Life
  • 5 years
  • Function
  • External Pulse Generation for Cardiac Rhythm
  • Instruments Type
  • Cardiac Medical Device
  • Frequency
  • 30-180 bpm
  • Measurement Range
  • 30-180 bpm
  • Equipment Type
  • Temporary Cardiac Pacing
  • Material
  • Medical Grade Plastic, Stainless Steel Components
  • Condition
  • New
  • Technology
  • Transcutaneous/Transvenous Pacing
  • Portable
  • Yes
  • Wall Mounted
  • No
  • Real-Time Operation
  • Yes
  • Noise Level
  • Low
  • Operating Type
  • Electric
  • Use
  • Temporary Cardiac Rhythm Management
  • Power Source
  • AC Mains/Rechargeable Battery
  • Power Consumption
  • 30 VA
  • Voltage
  • 110-240V AC, 50/60 Hz
  • Dimension (L*W*H)
  • 210 x 200 x 90 mm
  • Weight
  • 2.5 kg
  • Color
  • White with Blue Accents
  • Alarm Systems
  • Over/Under Pacing, Lead Disconnection, Battery Low
  • Controls
  • Rotary Knob and Touch Button Interface
  • Output Current Range
  • 10-200 mA
  • Pulse Width
  • Adjustable, 0.1-1.5 ms
  • Electrode Compatibility
  • Universal
  • Pacing Modes
  • VVI, AAI, DDD
  • Safety Features
  • Audible and Visual Alarms, Lock Setting, Emergency Mode Switch
  • User Interface
  • Intuitive Graphical Display with Status Indicators
  • Battery Backup Duration
  • Up to 5 hours
 
 

About Temporary Cardiac Pacing

Advin Temporary Cardiac Pacing Lead is designed for short-term cardiac pacing during surgical and emergency procedures. It ensures reliable electrical conduction to support heart rhythm management in critical cases. The lead is easy to place, flexible, and compatible with standard pacing equipment used in hospitals.

Advanced Features:

  • Flexible and smooth design for easy insertion

  • Reliable pacing performance with stable conduction

  • Compatible with standard pacing systems

  • Designed for short-term cardiac rhythm management

Product Keywords
Temporary Cardiac Pacing Lead, Cardiac Pacing Lead, Temporary Pacemaker Lead, Cardiology Pacing Device, Interventional Cardiology Lead

سلك تنظيم ضربات القلب المؤقت، سلك تنظيم ضربات القلب، سلك منظم ضربات القلب المؤقت، جهاز تنظيم ضربات القلب لأمراض القلب، سلك طب القلب التدخلي

Временный электрод для кардиостимуляции, электрод для кардиостимуляции, временный электрод для кардиостимулятора, кардиостимулятор, электрод для интервенционной кардиологии

Cable de estimulación cardíaca temporal, cable de estimulación cardíaca, cable de marcapasos temporal, dispositivo de estimulación cardíaca, cable de cardiología intervencionista

Sonde de stimulation cardiaque temporaire, sonde de stimulation cardiaque, sonde de stimulateur cardiaque temporaire, dispositif de stimulation cardiaque, sonde de cardiologie interventionnelle


Advanced Pacing Modes for Versatile Care

Accommodating various clinical scenarios, this device provides flexible pacing through VVI, AAI, and DDD modes. Whether single or dual-chamber pacing is needed, precise adjustments to rate, pulse width, and output ensure tailored therapy for each patient, enhancing both safety and therapeutic outcomes.


User-Centric Interface and Safety Alerts

With a digital LCD and intuitive graphical display, users can quickly assess device status. Rotary knobs and touch buttons grant seamless control. Audible and visual alarms proactively alert to over/under pacing, lead disconnection, or low battery, supported by lock and emergency features to bolster operational safety.


Reliable Power and Portability

Battery backup provides up to 5 hours of operation, and the device accepts a wide voltage range (110240V AC). Its robust design ensures low noise and minimal power demand (<30 VA), while the lightweight, portable build streamlines emergency response and in-hospital transport, maximizing critical care versatility.

FAQs of Temporary Cardiac Pacing:


Q: How is the temporary cardiac pacing device operated and controlled?

A: The device can be controlled via rotary knobs and touch buttons, allowing precise adjustment of pacing rate, output current, and pulse width. The intuitive graphical LCD display ensures that users can easily monitor and configure all pacing parameters, making operation straightforward even in urgent settings.

Q: What safety features are included for patient protection?

A: Multiple safety mechanisms are incorporated, such as audible and visual alarms for over/under pacing, lead disconnection, and low battery. The device also provides a lock setting to prevent unintentional adjustments and an emergency mode switch for immediate response during critical events.

Q: When is temporary cardiac pacing typically needed?

A: Temporary cardiac pacing is mainly required in situations of acute cardiac rhythm disturbances, such as heart block or bradycardia, especially in emergency rooms, ICUs, or during certain surgeries. It provides vital support until a permanent pacemaker can be installed or the underlying condition resolves.

Q: Where can this device be used effectively?

A: Designed for hospital and critical care environments, this equipment is ideal for use in ICUs, emergency departments, and during patient transport within medical facilities. Its portability and universal electrode compatibility support rapid deployment across various clinical settings.

Q: What is the process for setting up the device for use?

A: Begin by connecting universal electrodes and powering the device via AC mains or the rechargeable battery. Select the appropriate pacing mode (VVI, AAI, or DDD), adjust the rate, output current, and pulse width as needed. Always verify that alarms, battery status, and lock settings are properly configured before commencing pacing.

Q: What are the benefits of this device for temporary cardiac rhythm management?

A: This device provides precise, responsive cardiac pacing with flexible settings to accommodate diverse patient needs. Its portability, universal compatibility, real-time operation, and robust safety features deliver optimal support in critical scenarios, ensuring prompt, life-saving intervention.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Cardiology Products Category

Medical Disposable Products - Arterious

Medical Disposable Products - Arterious

Price 2.3 USD ($) / Piece

Minimum Order Quantity : 1 Piece

Color : Transparent with marked graduations

Use : Used for arterial blood collection, therapeutic, and diagnostic applications

Dimension (L*W*H) : Standard sizes as per medical requirements

Function : Facilitates arterial access and blood sampling

Transseptal Puncture and Access Needle

Transseptal Puncture and Access Needle

Price 60 USD ($) / Piece

Minimum Order Quantity : 1 Piece

Color : Silver (Needle), Blue/White (Handle)

Use : Cardiac Interventions, Electrophysiology Procedures

Dimension (L*W*H) : Various Lengths (e.g., 71cm, 89cm); 18G Diameter

Function : Transseptal puncture, Interatrial access

Dual Port Manifold

Dual Port Manifold

Price 2 USD ($) / Piece

Minimum Order Quantity : 1 Piece

Color : Silver

Use : Industrial Gas Flow Control

Dimension (L*W*H) : Approx. 12 x 4 x 4

Function : Dividing and Controlling Gas Flow

Radial Vascular Access Sheath

Radial Vascular Access Sheath

Price 6 USD ($) / Piece

Minimum Order Quantity : 1 Piece

Color : Transparent / Colored Hub

Use : Single Use

Dimension (L*W*H) : Varies by Size (47 Fr, Length 1025 cm)

Function : Peripheral vascular entry and arterial access



Back to top